Home » News » GHP Filter » wheel filter ghp membrane filter maximum operating pressure 2.1 bar

wheel filter ghp membrane filter maximum operating pressure 2.1 bar

World Pressure Filters – Parker Hannifin Maximum Allowable Operating Pressure (MAOP): 7000 psi (483 bar) Rated Fatigue Pressure: 6000 psi (414 bar) Design Safety Factor: 3:1 Operating Tempera...
Product Introduction

World Pressure Filters - Parker Hannifin

Maximum Allowable Operating Pressure (MAOP): 7000 psi (483 bar) Rated Fatigue Pressure: 6000 psi (414 bar) Design Safety Factor: 3:1 Operating Temperatures:-15°F (-26°C) to 250°F (135°C) Element Collapse Rating: Standard: 300 psi (21 bar) High Collapse: 2000 psi (138 bar) INDICATOR PORT IS AT 15° AS SHOWN ON ALL FILTERS EXCEPT WPF 1 WHICH IS AT 0°

Moduflow Series - Parker Hannifin

Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 200 psi (13.8 bar) Design Safety Factor: 2:1 Rated Fatigue Pressure: 150 psi (10.3 bar) Element Burst Rating: 70 psid (4.8 bar) Filter Materials: Head, Cover, Flanges: die cast aluminum Bowl: steel Operating Temperatures: Nitrile: -40°F to 225°F (-40°C to 107°C)

Desalination Membrane - an overview | ScienceDirect Topics

However, its installation costs are higher than for the other membranes. RO needs high-pressure pumps to work at approximately 15–27 bar for brackish water desalination and at 50–80 bar for seawater desalination [27, 28]. Large-scale RO desalination units currently operating typically have a water flux up to 400,000 m 3 /day.

Pressure Relief Valves | Parker NA

Parker’s pressure relief valves are designed to limit the upstream pressure by opening at a preset value and discharging the medium. Our range includes pressure relief valves in different mounting styles and for a variety of application areas: industrial as well as mobile, for the use in hydraulic and pneumatic systems, for fluid and gas handling, process control and refrigeration.

Acrodisc® 25 mm Syringe Filter, 0.45 µm PTFE Membrane, 1000

Acrodisc® Syringe Filters with PTFE Membrane - 0.45 µm, 25mm (1000/pkg) Maximum Operating Pressure (bar) 2.1 bar.

12AT/50AT Series - Parker Hannifin

Spin-On Filters Pressure Rating: Maximum Allowable Operating Pressure (MAOP): 150 psi (10.3 bar) Design Safety Factor: 2.5:1 Operating Temperatures:-40ºF to 225ºF (-40ºC to 107ºC) Canister Collapse Rating: 100 psid minimum Canister Condition Indicators: Gauge: Color coded 15/25 psi Gauge: Color coded vacuum Pressure Switch: Normally open 20

Stax™ mAx Clarification Platform - Depth Filtration System

Maximum Operating Pressure: 3 bar (44 psi) at 40 °C: 3 bar (44 psi) at 40 °C: 3.5 bar (50 psi) at 25 ºC 1.0 bar (14.3 psi) at 60 ºC: Maximum Differential Pressure: 1.5 bar (22 psi) 1.5 bar (22 psi) 2.4 bar (35 psi) at 25 ºC: Maximum Operating Temperature: 40 °C: 40 °C: 60 °C: Sterilization Autoclaving: 1 x 30 minute at 125 °C: 1 x 60

Separation and Purification Sciences Division Hollow fiber

Maximum Operating Pressure 58 psig @ 77°F (4 bar @ 25°C) Maximum DiFerential Pressure 28 psid @ 77°F (1.9 bar @ 25°C) Maximum Operating Temperature 104°F (40°C) Absolute Removal Ratings (nm) 5, 10, 20, 50, and 100 5, 10 10, 40 Filter Cartridge Integrity All Filters are Tested prior to release

Acrodisc wwPTFE Syringe Filters | Pall- MG Scientific

Acrodisc® Syringe Filter with wwPTFE membrane & wwPTFE Membrane Disc Filters, Pall. The “universal” membrane filter for all of your analytical filtration requirements. Avoid the expense and inconvenience of keeping a variety of filters on hand. Versatile filter for aqueous and aggressive organic solvent-based solutions.

high flow rate ghp membrane filter maximum operating pressure

Maximum Operating Pressure 58 psig @ 77°F (4 bar @ 25°C) Maximum DiFerential Pressure 28 psid @ 77°F (1.9 bar @ 25°C) Maximum Operating Temperature 104°F (40°C) Absolute Removal Ratings (nm) 5, 10, 20, 50, and 100 5, 10 10, 40 Filter Cartridge Integrity All Filters are Tested prior to release

Validation Guide Pall Supor Membrane Cassette

Membrane cassettes have operating limits for pressure, temperature, and pH (Table 6). (3) Clamping pressure must be set to the recommended level to avoid leaks. Two Supor TFF cassettes (PSM65F22-S022) were tested at ~1 bar (15 psi) TMP (Transmembrane Pressure) at 45 °C in 0.5 N NaOH for 30 hours (10 cycles of 3 hours).

The solution for high-flow, high-purity gas filtration

Materials Filter element Patented sintered nickel membrane filter Maximum operating conditions Maximum operating pressure: 50 bar (725 psig) SI2N0010R, SI2N0025R ...

Cell Culture Media Filtration

Filter capacity depends on the filtration membrane structure and the composition of the cell culture media; the latter vary widely in their constituents and formulations. In addition, Figure 1. Relationship between retentive performance and filter capacity. Filters with smaller pore size have lower capacity than sterilizing grade filters.

Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 um

Pall® 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000 . Filter Media: Glass Fiber / GH Polypro membrane (GHP, hydrophilic polypropylene)

PT Series - Parker Hannifin

The PT series filter is available in two diameters and three 2 1 5 7 6 3 11. PT Series ... Maximum Allowable Operating Pressure (MAOP): 150 psi ( 10.3 bar) ...