Hold-Up Maximum Maximum Typical Part Pore Volume Operating Operating Water Number Description Size (w/air purge) Temperature Pressure Flow Rate AP-4305 GxF/GHP 0.2 µm < 200 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 175 mL/min at 2.1 bar AP-4307 (210 kPa, 30 psi) at 21-24 °C (70-75 °F) (210 kPa, 30 psi) AP-4306
The conventional PEM fuel cells use a hydrated Nafion membrane and typically operate at temperatures below 100 • C. Control techniques for operating PEM fuel cells at maximum temperature have
Pall Laboratory. of filter media: hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without pre-wetting; GHP (hydrophilic polypropylene) membrane for low protein binding; and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and non-aggressive,. Compare this item.
Acrodisc® Syringe Filter with Luer-lock design facilitates use with syringes. Versapor® (acrylic copolymer) membrane filters feature large pore sizes ideal for prefiltration. Filters withstand normal syringe pressures up to 75psi. Maximum operating temperature for 25mm sizes 55°C. Color-coded by pore size for easy identification.
Male Luer slip and female Luer-lock. Filter. 0.2 micron. Sterile. Yes. Suitable for filter sterilizing dilute biological fluids. Low hold-up volume minimizes sample loss. HT Tuffryn (polysulfone) membrane is extremely low protein-binding. Maximum operating temperature: 55°C (131°F).
GH Polypro (GHP) Membrane Disc Filters - GH Polypro (GHP) Maximum Operating Temperature. 55 °C (131 °F) Minimum Bubble Point - IPA. 0.2 µm: 1 bar (100 kPa, 14 ...
high performance ghp membrane maximum operating temperature 55 C Rabbit® 3000 Datasheet Operating Voltage 1.8–3.6VDC Operating Current 2 mA/MHz @ 3.3V Operating Temperature -55° C to +85° C Maximum Clock Speed 55 MHz Digital I/O 56+ (arranged in seven 8-bit port
When the maximum operating temperature is below 650°F (343°C), it may be desirable to increase the maximum design temperature to 650°F (343°C) to provide greater flexibility. This is possible without altering the design of the vessel (thickness), because the maximum allowable design stress for most materials is the same for any design
micropore ghp membrane filter maximum operating temperature 55 C ghp membrane micropore on stock-Lab Consumables Supplier Jan 26, 2022 · Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences is a reliable and dependable addition to the Pall Filters fam
The Advantec unlaminated PTFE hydrophilic membrane filters are not permanently hydrophilic. Once wetted, they will become hydrophobic if allowed to dry. Also, they will become hydrophobic if autoclave sterilized or otherwise exposed to temperatures >100°C.
PVDF Membrane 0.2 µm: 140 µm (5.5 mils) 0.45 µm: 127 µm (5.0 mils) Nylaflo Membrane 0.2 and 0.45 µm: 127 µm (5.0 mils) Maximum Operating Temperature GHP Membrane: 55 ºC (131 ºF) PVDF, TF (PTFE), and Nylaflo Membranes: 100 ºC (212 ºF) Minimum Bubble Point – Water GHP Membrane 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138
Acrodisc Syringe Filters with GHP Membrane. Filter Media: wwPTFE (hydrophilic polytetrafluoroethylene) Maximum Operating Temperature: 55°C (131°F) Maximum ...
Acrodisc® syringe filters GHP membrane, diam. 25 mm, pore Acrodisc® syringe filters GHP membrane, diam. 25 mm, pore size 0.45 μm; find -Z259845 MSDS, related peer-reviewed papers, Tel: 8618057059123
unlaminated ghp acrodisc maximum operating temperature 55 C Acrodisc® Syringe Filters – Pall Corporation Maximum Operating Temperature. GHP, GHP GF, Nylon, Nylon GF, PES, and 13 mm PVDF: 55 C (131 F).
PTFE Unlaminated Membrane Filters. Our unsupported, hydrophobic, PTFE membrane filters are ideal for sterilization and venting applications involving air, gasses, and solvents/acids incompatible with most other filters. These PTFE filters are chemically and biologically inert, stable up to 260°C, and will withstand the majority of concentrated