10.3.1 Cast iron sectional boilers. These are used for hot water services with a maximum operating pressure of 5 bar and a maximum output in the order of 1500 kW. Site assembly of the unit is necessary and will consist of a bank of cast iron sections. Each section has internal waterways.
These offer high quality filtration for analytical samples. Certified for HPLC to ensure low extractables. Available in a broad range of membranes to meet sample compatibility requirements. The 25 mm Acrodisc is recommended for sample volumes from 5 to 100 mL. The 13 mm size is recommended for samples under 10 mL in volume.
Maximum Operating Temperature: 55°C (131°F) Maximum Operating Pressure: 0.2 and 0.45µm is 6.9 bar (100psi) GF/0.45µm is 6.3 bar (90 psi) Typical Water Flow Rate (mL/min at 2.1 bar (30psi)) 0.2µm, 25mm is 60 0.45µm, 25mm is 65 0.45µm, 25mm GF is 60: Typical Water Flow Rate (mL/min at 0.7 bar (10psi)) 0.2µm, 13mm is 17 0.45µm, 13mm is 28
micropore GH Polypro membrane maximum operating pressure 2.1 bar Acrodisc® 0.2 μm 25 mm Vent Filter Capsules no leakage was observed the pressure was slowly ramped up to 3.4 barg ( 50 psig). No leakage or water breakthrough was observed up to a test pressure of
NT. 0.7. Notes: 1. Airflow values calculated assuming linear relationship between volumetric airflow and differential pressure. 2. Water flows measured after prewetting with alcohol and calculated assuming linear relationship between flow and differential pressure. 3. Bubble points for 0.2µm, 0.45µm, and 3.0µm pore sizes measured using IPA
Hold-Up Maximum Maximum Typical Part Pore Volume Operating Operating Water Number Description Size (w/air purge) Temperature Pressure Flow Rate AP-4305 GxF/GHP 0.2 µm < 200 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 175 mL/min at 2.1 bar AP-4307 (210 kPa, 30 psi) at 21-24 °C (70-75 °F) (210 kPa, 30 psi) AP-4306
high operating pressures to avoid filter burst membrane for maximum chemical compatibility, AP-4307 2.1 bar at 21-24 °C (70-75 °F) at 2.1 bar ... GH Series High Pressure Compressed Air Filter (for pressures
Filter Media: Mustang E membrane; Housing: Polypropylene; Pore Size. 0.2 μm; Inlet/Outlet Connections. Female luer lock inlet, male slip luer outlet; Membrane Bed Volume. 0.12 mL; Maximum Operating Temperature and Pressure. 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical
Popular GH Polypro membrane maximum operating pressure 2.1 bar Natural Organic Matter Removal and Fouling in a Low Pressure Jan 08, 2014 · The NOM rejection and membrane fouling were performed on commercial polypropylene hollow fiber MF (Zena Membranes, Czec
Maximum operating conditions Maximum forward differential pressure: 0.35 MPa (3.5 bar, 50 psid, 3.5 kg/cm2) @ 25°C (77°F) Maximum reverse differential pressure: 0.27 MPa (2.7 bar, 40 psid, 2.8 kg/cm2) @ 20°C (68°F) Operating temperature: 60°C (140°F) PERFORMANCE DATA — GPM Diˆerential Pressure (bar) Diˆerential Pressure (psid) 26 4 81
PVC membrane housings from Applied Membranes are sturdy and reliable, offering optimal performance and protection against leaks. PVC membrane pressure vessels are ideal for use in reverse osmosis, microfiltration, nanofiltration, and ultrafiltration water treatment systems operating at pressures up to 200 psi. 2.5" Diameter PVC Housings.
Acrodisc PSF Syringe Filters - Medigene Sdn. Bhd.high operating pressures to avoid filter burst AP-4307 2.1 bar at 21-24 °C (70-75 °F) at 2.1 bar Acrodisc PSF GxF/GHP V o l u
PTFE Unlaminated Membrane Filters. Our unsupported, hydrophobic, PTFE membrane filters are ideal for sterilization and venting applications involving air, gasses, and solvents/acids incompatible with most other filters. These PTFE filters are chemically and biologically inert, stable up to 260°C, and will withstand the majority of concentrated
mL/min/cm 2 at 0.7 bar (70 kPa, 10 psi) 0.2 µm: 20 0.45 µm: 31 Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point - Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 kPa, 20 psi) Maximum versatility. Filters aqueous solutions or aggressive chemicals. Low protein binding membrane gives high recovery of critical
unlaminated PTFE membrane filter for metals-Analytical Feb 22, 2022 · PTFE Membrane Filters, Unlaminated, 1.0 Micron, 13mm, 50/Pk . Email to friends Share on Facebook - opens in a new window or tab Share on Twitter - opens in a new window or tab date: 2022-02-22