Home » News » GHP Filter » sterile ghp filters maximum operating pressure 2.1 bar

sterile ghp filters maximum operating pressure 2.1 bar

low protein binding membrane ghp syringe filter maximum low protein binding membrane ghp syringe filter maximum operating pressure 2.1 bar Supor® EKV Membrane Filters – Membrane Filters – Pall Max...
Product Introduction

low protein binding membrane ghp syringe filter maximum

low protein binding membrane ghp syringe filter maximum operating pressure 2.1 bar Supor® EKV Membrane Filters – Membrane Filters – Pall Maximum Operating Temperature * 60 ºC (140 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure* 5.4 bar (540 kPa, 80 psi) a

Acrodisc® Units with Mustang® E Membrane - Endotoxin Removal

Maximum Operating Temperature and Pressure. 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical Differential Pressure < 0.07 bar (7 kPa, 1 psi) @ 1 mL/min; Mean Flow Rate. 1 - 4 mL/min; flow rate will vary with type of solutions, concentration of proteins, and other components

micropore ghp membrane filter maximum operating pressure 2.1

micropore ghp membrane filter maximum operating pressure 2.1 bar Product Introduction Acrodisc PSF Syringe Filters - Medigene Sdn. Bhd. high operating pressures to avoid filter burst membrane for maximum chemical compatibility, AP-4307 2.1 bar at 21-24 °C (70-75 °F) at 2.1 bar ... GH Series High Pressure Compressed Air Filter (for pressures

high flow rate ghp membrane filter maximum operating pressure

Maximum Operating Pressure 58 psig @ 77°F (4 bar @ 25°C) Maximum DiFerential Pressure 28 psid @ 77°F (1.9 bar @ 25°C) Maximum Operating Temperature 104°F (40°C) Absolute Removal Ratings (nm) 5, 10, 20, 50, and 100 5, 10 10, 40 Filter Cartridge Integrity All Filters are Tested prior to release

STERILE SYRINGE FILTER

Operating Parameters Maximum Working Pressure: 5.5 bar (80 Psi) @ 25 oC (77 oF) oMaximum differential Pressure (forward): 4.1 bar (60 Psi) @ 25 oC (77 F) Maximum differential Pressure (reverse): 2.1 bar (30 Psi) @ 25 oC (77 oF) oMaximum Operating Temperature: 80 oC (176 F) Recommended Replacement Pressure: 2.4 bar (35.3 Psi) Safety

0.45 µm, Acrodisc® Syringe Filter with PVDF Membrane, 50/pkg

Maximum Operating Pressure (bar) 2.1 bar Maximum Operating Temperature (Metric) 82 °C Typical Flow Rate 144 mL/min at 2.1 bar (210 kPa, 30 psi) Overview Description Type Use Documents Datasheets Download: English Description Syringe filters are used in analytical chemistry applications to remove particulate contamination prior to analysis.

STERILE SYRINGE FILTER

Operating Parameters Maximum Working Pressure: 5.5 bar (80 Psi) @ 25 oC (77 oF) oMaximum differential Pressure (forward): 4.1 bar (60 Psi) @ 25 oC (77 F) Maximum differential Pressure (reverse): 2.1 bar (30 Psi) @ 25 oC (77 oF) oMaximum Operating Temperature: 80 C (176 oF) Recommended Replacement Pressure: 2.4 bar (35.3 Psi) Safety

Acrodisc® PSF Syringe Filters

AP-4364 GHP 0.2 µm < 125 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 215 mL/min at 2.1 bar AP-4564 (210 kPa, 30 psi) at 21-24 °C (70-75 °F) (210 kPa, 30 psi) AP-4566 AP-4357 GHP 0.45 µm < 125 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 300 mL/min at 2.1 bar

Description Specifications Integrity Testing

Filter Diameter 37 mm Effective Filtration Area 7.5 cm2 Typical Air Flow Rate 3.6 Lpm @ 0.2 bar (3 psi) Maximum Operating Temperature 100 °C (212 °F) Maximum Operating Pressure 4.1 bar (410 kPa, 60 psi) Minimum Bubble Point (IPA, 100%) 0.9 bar (90 kPa, 13 psi) Minimum Water Breakthrough Pressure 2.1 bar (210 kPa, 30 psi) Dimensions

Acro® 37 TF Device - Cole-Parmer

Maximum Operating Temperature 100 °C (212 °F) Maximum Operating Pressure 4.1 bar (410 kPa, 60 psi) Minimum Water Breakthrough 2.1 bar (210 kPa, 30 psi), bi-directional Typical Methanol Flow Rate 70 mL/min at 0.7 bar (70 kPa, 10 psi) Typical Air Flow Rate 3.58 L/min at 0.2 bar (20 kPa, 3 psi) Sterilization

Steridyne

140 °F @ 30 psig (60 °C @ 2.1 bar), gas 75 psig @ 100 °F (5.2 bar @ 38 °C), liquid 50 psig @ 100 °F (3.4 bar @ 38 °C), gas 15 psig @ 100 °F (1.0 bar @ 38 °C) Operating temperature range: Maximum temperature rating: Maximum temperature rating: Maximum operating pressure: Maximum operating pressure: Maximum reverse pressure:

Pall 4501 Acrodisc Syringe Filters with PTFE Membrane, 25 mm

Filter Media: Hydrophobic PTFE; Hold-Up Volume: 125 µL Housing Material: Polypropylene; Maximum Operating Pressure (bar): 2.1 bar; Maximum Operating Temperature (Metric): 100 °C; Pore Size (Removal Rating): 0.45 µm; Typical Flow Rate: 510 mL/min at 1.0 bar (100 kPa, 15 psi)

Pall® Acrodisc® glass fiber syringe filters diam. 37 mm, pore

Maximum Operating Temperature: 82°C (180°F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure: 4.1 bar (410 kPa, 60 psi) at 21 - 24ºC (70 - 75ºF) Typical Water Flow Rate: 795 mL/min at 1.0 bar (100 kPa, 15 psi)

Memflo Filter Cartridges – Mem-Sep Filtration

Vent Filters Bio-reduction Wine clarification; Operating Conditions: Maximum forward differential pressure: 6.0 bar (87psi) at 20°C Maximum operating temperature : 80°C Maximum reverse differential pressure: 2.1 bar at 20°C

Pall Acrodisc Filters - vgdusa.com

Flow rate: 78mL/min at 2.1 bar. 1.66. $229.17. 4907. Acrodisc Sterile Syringe Filter with 0.2um Fluorodyne II Membrane Membrane is hydrophilic polyvinylidene fluoride. For scale up. Polypropylene. Bacterial retention tested. Integrity testable. Filtration area: 2.8cm2. Female Luer-Lok inlet/male slip luer outlet. Flow rate: 130mL/min at 2.1 bar