Chlorine, aqueous . Saturated solution A F X . Chlorine, dry gas . 100% X X X . Chlorine, anhydrous liquid . X X X . Chlorine, liquid . 100% X X X . Chlorine water . X X X . Chloroacetic acid . Aqueous solution A n/a n/a . Chlorobenzene (mono) F X X . Chlorobromomethane . A n/a n/a . Chloroethanol . 100% A n/a n/a . Chloroform . 100% F X X
ghp membrane standard grade with high quality Mobile Phase Filtration - Analytical QC | Pall Corporation GH Polypro (GHP) Membrane Disc Filters · Maximum versatility.
The GH Polypro hydrophilic polypropylene membrane is ideal for aqueous solutions and offers maximum chemical compatibility for aggressive solvents. • 96.5% protein recovery. GH Polypro membrane is a low protein binding membrane. It removes unwanted particulate from samples with high recovery of critical proteins. • Low extractables. Our
Jan 8, 2023 · All-purpose, universal hydrophilic polypropylene membrane with maximum chemical compatibility when filtering both aqueous solutions and aggressive solvents. Low protein binding of GH Polypro membrane provides high recovery of critical proteinaceous samples. HPLC certified to assure that the filter will not add artifacts to your analysis.
Syringe Filters for HPLC & Sample Preparation | analytics-shop.comItems 1 - 50 of 1651 Hydrophilic membranes that can be used several times for filtration of aqueous or organic s Tel: 8618057059123 Email:market@aijirenvial.com
GH Polypro (GHP) Membrane Disc Filters All purpose, universal membrane with maximum chemical compatibility for both aqueous solutions and aggressive solvents Specifications Filter Media Hydrophilic polypropylene Pore Size 0.2 and 0.45 µm Typical Thickness 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) Typical Water Flow Rate mL/min/cm 2 at 0.7 bar
Description General-purpose hydrophilic polypropylene membrane filter for most analytical filtration requirements. Compatible filter for both aqueous solutions and aggressive organic solvent solutions. Low protein binding. HPLC certified for low levels of UV-absorbing extractables. Maximum operating temperature 55°C (131°F). More Information See full list on taylorscientific.com
Polypropylene membrane filters and prefilters can be safely disposed of by incineration. Unlike PTFE and PVDF filters, the polypropylene filters will not release harmful fluorine compounds. Polypropylene filters have been discontinued as of October 6, 2020; remaining inventory can be found in our Clearance Section .
Once wetted, the sorbent needed to be equilibrated with aqueous solution to Acrodisc wwPTFE Syringe Filters | Pall - MG Scientific. Acrodisc Syringe Filter with GHP membrane & GH Polypro (GHP) Membrane Disc Filters Versatile filter for aqueous and aggressive organic solvent-based ... PFAS Analysis in the Environment - Aijiren
Pall Life Sciences GH Polypro (GHP) Membrane Disc Filters, Model 60189, Pack of 100-All-purpose, universal hydrophilic polypropylene membrane with max Free Shipping & Rewards 5% Back and Free Shipping on all orders over $49!
Since polypropylene is a pure hydrocarbon material, there are no disposal problems relating to halogen content with PP membrane in contrast with other hydrophobic membranes such as PVDF or PTFE. PDF [ 2 Page / 111K ] Features. hydrophobic; Superior thermo stability; Compatible with aqueous and alcoholic solutions and solvents; suitable for HPLC
The prefilters provide high particle retention, high dirt holding capacity and low pressure drop. They are designed for filtration of organic solvents, but they can also be used, once properly wetted with alcohol, for the filtration of aqueous solutions. Polypropylene prefilter Features & Benefits Compatible with aggressive solvents
Membrane disc filters, GH Polypro (GHP) Supplier: Pall Laboratory Ratings: (No Reviews) Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including Centrifugal Devices, Syringe Filters, Filter Plates, and Membrane Filter Discs.
Optimum Growth™ System Mammalian & insect cell culture offerings supporting 50-60% fill volumes.
GH Polypro (GHP) Membrane Disc Filters Hydrophilic polypropylene membrane with maximum chemical compatibility when filtering both aqueous solutions and aggressive solvents. High recovery of critical proteinaceous samples due to low protein binding. HPLC certified. 47mm diameter. Pore size: 0.45um.