Popular ghp membrane maximum operating temperature 55 C Ghp Membrane at Thomas Scientific Pall Laboratory. of filter media: hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without pre-wetting; GHP (hydro
Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point - Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 kPa, 20 psi) Maximum versatility. Filters aqueous solutions or aggressive chemicals. Low protein binding membrane gives high recovery of critical proteinaceous samples. HPLC certified. Provides assurance
Chemical Compatibility Maximum Operating Temperature wwPTFE, Nylon, PES: 55 °C (131 °F) PTFE, PVDF: 100 °C (212 °F) ... exceed maximum operating pressure.
HPLC Mobile Phase Filtration Membranes - Pall. Filter Media GH Polypro (GHP, hydrophilic polypropylene), TF (PTFE, hydrophobic polytetrafluoroethylene), PVDF (hydrophilic polyvinylidene fluoride), and Nylaflo™ (hydrophilic nylon) membranes Pore Size 0.2 and 0.45 µm Typical Thickness GHP Membrane 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) TF (PTFE) Membrane 0.2 µm: 139 µm
The GH Polypro (GHP) hydrophilic polypropylene membrane offers maximum chemical compatibility. GHP membrane offers low protein binding (96.5% recovery), and low extractables. Devices can be spun at 14,000g with leak-free operation. This is only for Pall Life Sciences, Model ODGHPC34.
Acrodisc® 13 mm syringe filters featuring a hydrophilic polyvinylidene fluoride (PVDF) minispike outlet. Buy these syringe filters online. They have a hold-up volume less than 14 µL with 55 °C as the maximum operating temperature.
Maximum Operating Temperature: 55°C (131°F) Maximum Operating Pressure: 0.2 and 0.45µm is 6.9 bar (100psi) GF/0.45µm is 6.3 bar (90 psi) Typical Water Flow Rate (mL/min at 2.1 bar (30psi)) 0.2µm, 25mm is 60 0.45µm, 25mm is 65 0.45µm, 25mm GF is 60: Typical Water Flow Rate (mL/min at 0.7 bar (10psi)) 0.2µm, 13mm is 17 0.45µm, 13mm is 28
This discount applies to online credit card orders only from shop.pall.com. Membrane with Chemical Compatibility for ... Maximum Operating Temperature. 55 °C ...
Maximum Operating Temperature: 55°C Pall® Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications.
Excellent chemical compatibility with esters, bases and alcohols. Specifications Materials of Construction Filter Media: Nylon Housing: Polypropylene Effective Filtration Area 2.8 cm2 Inlet/Outlet Connections Female luer-lok inlet, male slip luer outlet Typical Hold-up Volume (with air purge) < 50 µL Maximum Operating Temperature 55 °C (131 °F)
GH Polypro (GHP) Membrane Disc Filters - Separations. GH Polypro (GHP) Membrane Disc Filters All purpose, universal membrane with maximum chemical compatibility for both aqueous solutions and aggressive solvents Specifications Filter Media Hydrophilic polypropylene Pore Size 0.2 and 0.45 µm Typical Thickness 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) Typical Water Flow Rate mL/min
Maximum Operating Temperature GHP Membrane: 55 ºC (131 ºF) PVDF, TF (PTFE), and Nylaflo Membranes: 100 ºC (212 ºF) Minimum Bubble Point – Water GHP Membrane 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 kPa, 20 psi) PVDF Membrane 0.2 µm: 2.3 bar (230 kPa, 34 psi) 0.45 µm: 1.1 bar (110 kPa, 16 psi) Nylaflo Membrane
solvent compatibility ghp membrane online Column & Consumables – Tradesworth Group Membrane Type (PTFE, GHP, PVDF, Nylon) — Typically, the first step in selecting a suitable filter is to choose a membrane that is chemically comp
Membrane with Chemical Compatibility for Aqueous Solutions and Aggressive Solvents - Maximum versatility. Maximum Operating Temperature - 55 °C (131 °F ...
Maximum Operating Temperature. 55 °C (131 °F) Minimum Bubble Point - IPA. 0.2 µm: 1 bar (100 kPa, 14.5 psi) 0.45 µm: 0.63 bar (63 kPa, 9.1 psi)