Home » News » GHP Filter » solvent compatibility ghp syringe filter maximum operating temperature 55��C

solvent compatibility ghp syringe filter maximum operating temperature 55��C

Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 um Solvent Waste Systems. Pall® 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000 …...
Product Introduction

Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 um

Solvent Waste Systems. Pall® 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000 ... Maximum Operating Temperature ...

Nylon Syringe Filters, Sterlitech, 0.45 Micron, 25mm, 100/Pk - 14

The maximum recommended operating temperature for the syringe filters when used with compatible fluids is 60°C. When operating at high temperatures, the housing strength is reduced and it may be necessary to limit the applied pressure.

Membrane Filter Chemical Compatibility Chart - Support

Syringe Filter Housings. 1) Syringe filter housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices. 2) Solutions at temperatures up to 100°C can be filtered using syringe filters. 3) Syringe filters can be sterilized by autoclave at 125°C for 15 minutes.

Acrodisc Syringe Filter PALL | High Performance Liquid

Acrodisc PSF syringe filters are Zymark* and SOTAX* Automation. Certified to ensure smooth operation and worry-free performance 24. hours a day in automated workstations. Avoid the expense and inconvenience of keeping a variety of filters on. hand. Versatile filter for aqueous and aggressive organic solvent-based.

Acrodisc® Syringe Filters with Versapor® Membrane

Maximum Operating Temperature 0.8 µm: 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) 10 µm: 82 ºC (180 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure

Choice™ Polypropylene (PP) Syringe Filters

Economic Choice Syringe Filters are available in a variety of sizes and membrane types to meet any application need. Choice Polypropylene (PP) Syringe Filters 0.2 µm, 25 mm, 100 Pk. Choice Polypropylene (PP) Syringe Filters 0.45 µm, 25 mm, 100 Pk. Choice Polypropylene (PP) Syringe Filters 0.2 µm, 13 mm, 100 Pk.

OSHA Technical Manual (OTM) - Occupational Safety and Health

OSHA Instruction TED 01-00-015. The OSHA Technical Manual (OTM) provides technical information about workplace hazards and controls to OSHA’s Compliance Safety and Health Officers (CSHOs). This information supports OSHA’s enforcement and outreach activities to assure safe and healthful working conditions for working men and women.

GH Polypro (GHP) Membrane Disc Filters - Separations

Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point - Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 kPa, 20 psi) Maximum versatility. Filters aqueous solutions or aggressive chemicals. Low protein binding membrane gives high recovery of critical proteinaceous samples. HPLC certified. Provides assurance

Cole-Parmer PES Sterile Chromatography Syringe Filters; 0

PES Syringe Filters are naturally low protein binding and sample absorbing, and have a wide chemical compatibility for both aqueous and organic solvent filtration. Recommended for filtering critical biological sampling, tissue culture media, additives, serum and buffers. Maximum use temperature is 50°C (122°F).

PALL ACRODISC SYRINGE FILTERS - ww-w.vgdusa.com

4219. Acrodisc Syringe Filter 25mm 0.45um. Hydrophobic PTFE membrane for exceptional chemical and temperature compatibility. HPLC certified for low level UV-absorbing extractables. Polypropylene housing. Female Luer-Lok inlet standard male slip Luer outlet. \<100uL hold-up volume. 50/pk. 200/cs.

Acrodisc wwPTFE Syringe Filters | Pall- MG Scientific

Maximum Operating Temperature: 55°C (131°F) Maximum Operating Pressure: 0.2 and 0.45µm is 6.9 bar (100psi) GF/0.45µm is 6.3 bar (90 psi) Typical Water Flow Rate (mL/min at 2.1 bar (30psi)) 0.2µm, 25mm is 60 0.45µm, 25mm is 65 0.45µm, 25mm GF is 60: Typical Water Flow Rate (mL/min at 0.7 bar (10psi)) 0.2µm, 13mm is 17 0.45µm, 13mm is 28

Syringe Filter Membrane Compatibility Chart

Use the information in this table to determine the ability of a specific syringe filter membrane to withstand exposure to a solvent. All concentrations are 100% unless noted. Syringe Filter Membrane Compatibility Chart

Hydrophilic Polypropylene at Thomas Scientific

Polypropylene Membrane Target Syringe Filters. National Scientific. available filtration area, and reduces back pressure when filtering samples high in particulates. Membrane: Hydrophilic Polypropylene Housing: medical grade, virgin polypropylene Connections: enhanced female Luer-Lok inlet, male slip outlet Max. operating temperature: 110°C

Syringe Filters - Ciro Manufacturing Corporation

Maximum Operating Temperature 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 13 mm: 6.9 bar (690 kPa, 100 psi) 17 mm: 130 psi 25 mm: 4.1 bar (410 kPa, 60 psi) at 21 - 24 ºC (70 - 75 ºF); 2.1 bar (210 kPa, 30 psi) at 55 ºC (131 ºF) Typical Water Flow Rate with Nylon membrane- mL/min at 2.1 bar (210 kPa, 30 psi)

AMTAST RC Regenerated Cellulose Syringe Filters Non Sterile

Maximum Operating Temperature: 50°C. Maximum Operating Pressure: 87 psi (6.0bar) at 20 °C. Regenerated Cellulose syringe filters are used for low nonspecific binding applications, as well as tissue culture media filtration and general biological sample filtration.