50:50 methanol:water, then vortexed and filtered with a 0.2 um GHP syringe filter. To prepare spikes, 100 µL of the 2x prep is diluted with 4.8 mL of 50:50 methanol:water and 100 µL of 100 ppb spike solution in a scintillation vial, then vortexed and filtered with a 0.2 um GHP filter. Final expected concentration of spike in vial is 2.0 ppb.
Maximum Operating Temperature: Maximum 100 °C (212 °F) at 2.1 bar (210 kPa, 30 psi) Sterilization: Provided non-sterile. If needed, autoclave at 121°C (250°F) at 1.0 bar (100 kPa, 15 psi) for a maximum of 15 min.
Diameter 25 mm Filtration Area 3.9 cm² Filter Media Hydrophobic PTFE Flow Rate 245 mL/min at 1.0 bar (100 kPa, 15 psi) Hold-Up Volume <125 µL Housings Polypropylene Maximum Operating Pressure 2.1 bar Max.
The premium Titan3 syringe filter range provides even higher levels of confidence • Color coding for easy identification and selection of the correct membrane and pore size • 30 mm products pressure rated to 120 psi/15 bar • Integrated prefilter options for enhanced removal of particulates Both Titan3 and Target2 syringe filters
109. McKesson Brand #MSF475. Syringe Disc Filter McKesson 0.2 Micron, Sterile, Male / Female Luer-Lock PES. Log in for pricing and availability. Log In to Order View Alternatives. #943839. 417. B. Braun #418012. Syringe Tip Cap Multi-AD® Red, Luer Lock.
Acrodisc 25 mm syringe filters with glass fiber maximize throughput prefiltration of particulate-laden samples. They can be used alone or in series with another Acrodisc syringe filter. 25 mm Standard Acrodisc Syringe Filters are ideal for sample volumes of ≤ 100 mL and feature an effective filtration area of 2.8 cm 2.
STERILE SYRINGE FILTER These filters are designed for applications where sterility of the affluent is mandatory (Sterile Compounding and Pharmaceutical use). The product contains a pharmaceutical grade PTFE membrane Sterilizing Grade and the filters are built in a 10,000-class clean room, flushed, dried and 100% integrity tested prior to packaging.
Because Mycoplasma are able to penetrate 0.2 µm rated sterile filters, the industry specifically developed finer filter membranes (0.1 µm) for the successful retention of Mycoplasma. It is the highly asymmetric structure and the perfect fit between the 0.2 µm prefilter layer and the 0.1 µm final membrane which ensures an unmet combination
Accurate pore size rating – Acrodisc PSF syringe filters are more retentive than standard 25 mm devices and are available with single-layer membranes or multilayer glass fiber prefilters.
9.75”,10”20”,30”,40”. Seal Material. S = Silicone E = EPDM B = NBR F = E-FKM V = Viton T=Teflon. Maximum Operating Temperature. PP : 80°C. Maximum Operation Differential Pressure. 4.2 Bar @ 21°C. 2.1 Bar @ 80°C. 011 Hydrophobic PTFE Hydrophilic PTFE Pleated Filter Cartridge.pdf.
Syringe Filters Body: Polypropylene Recommended Operating Conditions Filter Cartridges Up to 70 °C (158 °F) continuous operating temperature and higher short-term temperatures during CIP to the following limits: MURUS Disposable Filter Capsules Up to 25 °C ( 77 °F) @ 5.5 barg (79.7 psig) Up to 60 °C (140 °F) @ 2.8 barg (40.6 psig)
Maximum Allowable Back Pressure 2 bar (29 psi) at 20°C; 1.5 bar (21.8 psi) at 50°C (126) 2 bar (29 psi) at 20°C (39)
Reactor 40 Hydraulic Autopilot GHP 1.2L Pump Reactor 40 ECU 10 Shadow Drive GHC 20 010-00705-64: GHP 1.2L Pump Hydraulic Low-cost option for dual-cylinder applications with total cylinder volumes from 10 to 24 cubic inches Reactor 40 Hydraulic Autopilot GHP 2.0L Pump Reactor 40 ECU 10 Shadow Drive GHC 20 010-00705-63: GHP 2.0L Pump Hydraulic
Filter Efficiency Rating: 99.99% to 99.99999%, depending on filter type. Element Change Interval: 12 months for V, ZP, XP elements / 3 months or max. 1500 hours of operation for A elements. Maximum Flow Rate: 188 to 2787 (@100 barg) m3/hour, 111 @ 1450 psig to 1640 @ 1450 psig CFM. Maximum Operating Pressure: 100 barg, 1450 psig.
Syringe Filters Body: Polypropylene Recommended Operating Conditions Filter Cartridges Up to 70 °C (158 °F) continuous operating temperature and higher short-term temperatures during CIP to the following limits: MURUS Disposable Filter Capsules Up to 25 °C ( 77 °F) @ 5.5 barg (79.7 psig) Up to 60 °C (140 °F) @ 2.8 barg (40.6 psig)