Home » News » GHP Filter » polypropylene housing ghp membrane maximum operating pressure 2.1 bar

polypropylene housing ghp membrane maximum operating pressure 2.1 bar

Acrodisc® Units with Mustang® E Membrane – Endotoxin Removal Filter Media: Mustang E membrane; Housing: Polypropylene; Pore Size. 0.2 μm; Inlet/Outlet Connections. Female luer lock inlet, mal...
Product Introduction

Acrodisc® Units with Mustang® E Membrane - Endotoxin Removal

Filter Media: Mustang E membrane; Housing: Polypropylene; Pore Size. 0.2 μm; Inlet/Outlet Connections. Female luer lock inlet, male slip luer outlet; Membrane Bed Volume. 0.12 mL; Maximum Operating Temperature and Pressure. 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical

Acro® 50 Vent Devices with PTFE Membrane

Housing: Polypropylene Filter Diameter 50 mm Effective Filtration Area 19.6 cm2 Typical Air Flow Rates 0.2 µm: 8 Lpm at 0.2 bar (20 kPa, 3 psi) 0.45 µm: 12 Lpm at 0.2 bar (20 kPa, 3 psi) 1 µm: 15 Lpm at 0.2 bar (20 kPa, 3 psi) Maximum Operating Temperature 130 °C (266 °F) at 1.0 bar (100 kPa, 15 psi) Maximum Operating Pressure

BPS Capsule Filters

Maximum Operating Parameters Liquid Operational Pressure 80 psi (5.5 bar) at 20 °C (68 °F) Gases Operational Pressure 60 psi (4.1 bar) at 20 °C (68 °F) Operating Temperature 43 °C (110 °F) at 30 psi (2.1 bar) in water Forward Differential Pressure 50 psid (3.4 bard) at 20 °C (68 °F) Reverse Differential Pressure 40 psid (2.7 bard) at 20

Protec ter 1 - Meissner

Maximum Operating Pressure & Temperature, Liquids Maximum Operating Pressure & Temperature, Gas 75 psig @ 32°F to 100°F 50 psig @ 32°F to 100°F (5,2 bar @ 0°C to 38°C) (3,4 bar @ 0°C to 38°C) 45 psig @ 140°F 30 psig @ 140°F (3,1 bar @ 60°C) (2,1 bar @ 60°C) UltraCap® H.D. Model

AcroPak™ 300 Capsule with PTFE Membrane

Housing Diameter With Vent: 6.7 cm (2.6 in.) Housing Diameter Without Vent: 5.3 cm (2.1 in.) Inlet/Outlet Connections Stepped hose barbs 6.4 - 12.7 mm (1/4 - 1/2 in.) diameter Typical Hold-Up Volume < 6 mL Maximum Operating Temperature 60 °C (140 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 4.1 bar (410 kPa, 60 psi) at ambient

Pall 4433 DMSO-Safe Syringe Filter Nylon Membrane, 25mm

Housing: Polypropylene; Sterilization: Sterilized by ethylene oxide and individually packaged; Maximum Operating Temperature: 55 °C (131 °F) Maximum Operating Pressure: 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate: 60 mL/min at 2.1 bar (210 kPa, 30 psi) Typical Hold-Up Volume (with air purge): < 50 Μl

Acrodisc wwPTFE Syringe Filters | Pall- MG - MG Scientific

Maximum Operating Temperature: 55°C (131°F) Maximum Operating Pressure: 0.2 and 0.45µm is 6.9 bar (100psi) GF/0.45µm is 6.3 bar (90 psi) Typical Water Flow Rate (mL/min at 2.1 bar (30psi)) 0.2µm, 25mm is 60 0.45µm, 25mm is 65 0.45µm, 25mm GF is 60: Typical Water Flow Rate (mL/min at 0.7 bar (10psi)) 0.2µm, 13mm is 17 0.45µm, 13mm is 28

Acrodisc® Syringe Filters With Universal Membranes - GxF/0.2

3.9 cm² Filter Media Glass Fiber / GH Polypro membrane (GHP, hydrophilic polypropylene) Hold-Up Volume <200 µL Housing Material Polypropylene Maximum Operating Pressure (bar) 4.1 bar Maximum Operating Temperature (Metric) 55 °C Typical Flow Rate 175 mL/min at 2.1 bar (210 kPa, 30 psi) Overview Description Type Use

Mustang E Membrane - STEMart

Specification. Membrane: Highly cross-linked quaternized amine Mustang E membrane. Material of Housing: Polypropylene. Pore Size: 0.2 μm. Inlet/Outlet Connections: Female luer lock inlet, male slip luer outlet. Membrane Bed Volume: 0.12 mL. Maximum Operating Temperature and Pressure: 2.1 bar at 60 °C or 5.5 bar at 21 - 24 °C.

Acrodisc® PSF Syringe Filters

typical hold-up maximum maximum typical part pore volume operating operating water number description size (w/air purge) temperature pressure flow rate ap-4305 gxf/ghp 0.2 µm < 200 µl 55 °c (131 °f) at 2.1 bar 4.1 bar (410 kpa, 60 psi) 175 ml/min at 2.1 bar ap-4307 (210 kpa, 30 psi) at 21-24 °c (70-75 °f) (210 kpa, 30 psi) ap-4306 ap-4557

Supply Hydrophilic PVDF Membrane Pleated Filters, PVDF Filter

Maximum Operating Temperature: 100℃(212℉) Max. Differential Pressure: 4.8 bar at 20℃(70 psi at 68℉) 2.1 bar at 100℃(30 psi at 212℉) Maximum reverse pressure: 40 psid @ 70°F (2.8 bar @ 21°C) Recommended Change Out Differential Pressure: 2.4 bar (35 psid) Sterilization Temperature Time

PureFlo® Polypropylene Membrane Filter Capsules

Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Di˛erential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Di˛erential Pressure: 2.1 bar (30psi) at 68°F/20°C Maximum Operating Temperature: PP & Gamma PP

Supply Hydrophilic PTFE Membrane Pleated Filters, PTFE Filter

Maximum Operating Temperature: 90℃(194℉) Max. Differential Pressure: 4.8 bar at 20℃(70 psi at 68℉) 2.1 bar at 90℃(30 psi at 194℉) Recommended Change Out Differential Pressure: 2.4 bar (35 psid) Sterilization Temperature Time: 121˚C (250˚F) for 30 minutes at 1.0 bar (14 psi), multiple cycles

amcPTFECap--American Membrane Corporation

Maximum Operating Temperature 60 °C at 30 psi (2.1 bar) Sterilization 121 °C for multiple cycles at 15 psi (1.0 bar) Maximum Operating Pressure: 60 psi (4.1 bar) at ambient temperature : Minimum Bubble Point: 0.1 μm: 21 psi (1.5 bar) in ethanol 0.2 μm: 15 psi (1.1 bar) in ethano : Typical Water Flow Rate (after ethanol prewet) 0.1 μm:

Pall 4501 Acrodisc Syringe Filters with PTFE Membrane, 25 mm

Housing Material: Polypropylene; Maximum Operating Pressure (bar): 2.1 bar; Maximum Operating Temperature (Metric): 100 °C; Pore Size (Removal Rating): 0.45 µm; Typical Flow Rate: 510 mL/min at 1.0 bar (100 kPa, 15 psi)

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.