The 25 mm Acrodisc is recommended for sample volumes from 5 to 100 mL. The 13 mm size is recommended for samples under 10 mL in volume. The 4 mm size is for samples under 2 mL. PP housing with Luer fittings. GHP - hydrophilic PP membrane suitable for both aqueous and organic samples; GXF - multi-layered glass fiber prefilter
relationship between pressure head and pressure is given in equation [4]. SG p psi H ft fluid 2.31 ( ) × = [4] where (H) is the pressure head, (p) the pressure and (SG) the specific gravity of the fluid. If the shut-off pressure exceeds the allowable operating pressure as calculated by the ASME code, then pressure relief devices may have to be
Maximum Operating Temperature: 55°C (131°F) Maximum Operating Pressure: 0.2 and 0.45µm is 6.9 bar (100psi) GF/0.45µm is 6.3 bar (90 psi) Typical Water Flow Rate (mL/min at 2.1 bar (30psi)) 0.2µm, 25mm is 60 0.45µm, 25mm is 65 0.45µm, 25mm GF is 60: Typical Water Flow Rate (mL/min at 0.7 bar (10psi)) 0.2µm, 13mm is 17 0.45µm, 13mm is 28
Pall 25MM ACRODISC 0.45UM wwPTFE 1000/PK. “Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521
3.9 cm² Filter Media Glass Fiber / GH Polypro membrane (GHP, hydrophilic polypropylene) Hold-Up Volume . 200 µL Housing Material Polypropylene Maximum Operating Pressure (bar) 4.1 bar Maximum Operating Temperature (Metric) 55 °C Typical Flow Rate 175 mL/min at 2.1 bar (210 kPa, 30 psi) Overview Description Type Use
The Chemlock PP housing has fully molded fittings in several fitting types and sizes, in an extremely compact housing head . design. The Chemlock housing is offered in a universal (nominal 10") length and in a 20" length to accommodate a wide variety of cartridges.
Filtration is the mechanical-physical operation which is used for the Because of their hydrophobic nature, the polypropylene membranes are best suited GVS Life Sciences -.::SPAN INC::. GVS Life Sciencespolypropylene membrane filters are composed of pure polypropylene Operating Pressure: 4 bar. Premier Performance. • PTFE membrane and ...
Acrodisc® Syringe Filters with GHP Membrane - Acrodisc® Syringe Filters Housing: Polypropylene; ... at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure. 13 ...
In fact, the Platinum Resistance Temperature Detector, or RTD Pt100, is used today as an interpolation standard from the oxygen point (-182.96°C) to the antimony point (630.74°C).
Acrodisc® Syringe Filters with PTFE Membrane - HPLC/UHPLC Acrodisc® Syringe Filters with PTFE Membrane - 0.2 µm, 13mm, minispike outlet (100/pkg 300/cs) Product ID4552 Pore Size0.
Pall AcroDisc Syringe Filters shipped worldwide by VOIGT GLOBAL DISTRIBUTION INC PO Box 1130, Lawrence, Kansas 66044 USA Toll Free in the USA: 877-484-3552 or 1.785.393.8509 International Fax: 1.913.273.0458 - please include your e-mail in the fax for a reply.
Supor® EKV Membrane Filters - Membrane Filters - PallMaximum Operating Temperature * 60 ºC (140 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure* 5.4 bar (540 kPa, 80 p
Filter Media: Mustang E membrane; Housing: Polypropylene; Pore Size. 0.2 μm; Inlet/Outlet Connections. Female luer lock inlet, male slip luer outlet; Membrane Bed Volume. 0.12 mL; Maximum Operating Temperature and Pressure. 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical
Housing: Polypropylene. 25 mm. Pore Size: 0.45 um. Typical Hold-up Volume: \< 100 uL. Maximum Operating Temperature: 100[degree]C. Maximum Operating Pressure: 4.1 bar. 6. AP-4502. Acrodisc 25mm Premium Syringe Filter Nylon hydrophilic membrane has excellent compatibility with esters bases and alcohols and requires no prewetting.
micropore GH Polypro membrane maximum operating pressure 2.1 bar Acrodisc® 0.2 μm 25 mm Vent Filter Capsules no leakage was observed the pressure was slowly ramped up to 3.4 barg ( 50 psig). No leakage or water breakthrough was observed up to a test pressure of