Home » News » GHP Filter » micropore ghp acrodisc effective filtration area 3.9 cm2

micropore ghp acrodisc effective filtration area 3.9 cm2

Stability of Epinephrine at Standard Concentrations All standards were passed through a 0.45-μm microfilter (Acrodisc GHP syringe filter, Gelman, Ann Arbor, Michigan; lot A10647284) to prevent inje...
Product Introduction

Stability of Epinephrine at Standard Concentrations

All standards were passed through a 0.45-μm microfilter (Acrodisc GHP syringe filter, Gelman, Ann Arbor, Michigan; lot A10647284) to prevent injection of impurities onto the column. A 5-point calibration curve was prepared, with a blank (water only) at the beginning of each run, to ensure no carryover from one run to the next.

PALL ACRODISC SYRINGE FILTERS - ww-w.vgdusa.com

Pall AcroDisc Syringe Filters shipped worldwide by VOIGT GLOBAL DISTRIBUTION INC PO Box 1130, Lawrence, Kansas 66044 USA Toll Free in the USA: 877-484-3552 or 1.785.393.8509

Acrodisc Syringe Filters Chemical Compatibility Guide | High

There are two lines of Acrodisc syringe filters. From the perspective of extractables, the standard Acrodisc and the Acrodisc PSF syringe filters are identical, with the exception that the effective filtration area of the PSF prod-uct line is larger. It is 31% greater based on the 3.9 cm2 EFA compared to the 2.8 cm2 of the standard Acrodisc.

solvent compatibility ghp acrodisc effective filtration area

Effective Filtration Area 3.9 cm² Sample Volume Range 1 – 12 mL Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet Typical Hold up Volume Hold up volume < 2 mL, with total sample volume = 12 mL Ordering Information Acrodisc PSF WBC Syringe Filter with Leukosorb Membrane Performance Unfiltered Sample 4 Nucleated WBCscatter e

Pall_Analytical_Bro.pdf | High Performance Liquid

Relative Throughput (EFA) < 150 mL (3.9 cm2) Filter Formats Acrodisc PSF Syringe Filters 25 mm Acrodisc PSF Syringe Filter: designed and automation certified to address the specific requirements of automated workstations. 25 mm Acrodisc PSF GxF Syringe Filter: multi-layered glass prefilter to maximize throughput and meet the requirements of

(PDF) ZnO nanocrystals shuttled by extracellular vesicles as

Aim: The effective application of nanoparticles in cancer theranostics is jeopardized by their aggregation in biological media, rapid degradation and clearance. The design of biomimetic nanoconstructs with enhanced colloidal stability and

Syringe Filters - Pall Corporation

For example, Pall supply both a traditional ring molded 25 mm syringe filter and the Premium Syringe Filter (PSF) 25 mm syringe filter. The PSF syringe filter has a much larger effective filtration area compared with the older traditional model, 3.9 cm 2 compared to 2.8 cm 2. Therefore, this gives the PSF syringe filter a much improved

PTFE Syringe Filters - Polytetrafluoroethylene Syringe

Acrodisc Ic 13 Mm Syringe Filter, Effective filtration area: 0.1cm2 for 4mm, 0.8 cm2 for 13mm & 3.9 cm2 for 25mm & Sterilization: ETO.

PTFE membrane filter for chemicals Pall Acrodisc-Analytical

Feb 22, 2022 · As well as being suitable for the filtration of organic solvents in applications such as HPLC and UHPLC sample preparation, the hydrophobic nature of the PTFE membrane makes these syringe filters ideal to use in gas filtration or as a moisture barrier in venting applications. 25 mm Standard Acrodisc Syringe Filters.

sterile ptfe 0.2 micron filter for medicine-PTFE Membrane Filter

Emflon® PFRW Filter Cartridges - Pall ShopThe filter element features Pall's advanced 0.2 micron rated polytetrafluoroethylene (PTFE) double-layer membranes, pleated with very hig

Acrodisc Syringe Filter PALL | High Performance Liquid

Specifications Materials of Construction Filter Media: GH Polypro membrane (GHP, hydrophilic polypropylene) Housing: Polypropylene GxF Prefilter: Binder-free borosilicate glass. Pore Size GHP Membrane: 0.2 and 0.45 m Glass Fiber: 1 m GxF Prefilter: 40 - 1 m Effective Filtration Area 13 mm: 1.0 cm2 25 mm PSF: 3.9 cm2

(PDF) Size-Exclusion Chromatography - Academia.edu

All samples analyzed were filtered with a 0.45- g) for 5 min. The grids were recovered and dried with bibulous mm GHP Acrodisc filter membrane (Pall Gelman Sciences) be- paper, stained with phosphotungstic acid (3%, pH 6.0) for 1 fore injection.

Acrodisc® WBC (White Blood Cell) Syringe Filter

Effective Filtration Area 3.9 cm² Sample Volume Range 1 – 12 mL Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet Typical Hold up Volume Hold up volume < 2 mL, with total sample volume = 12 mL Ordering Information Acrodisc PSF WBC Syringe Filter with Leukosorb Membrane Performance Unfiltered Sample 4 Nucleated WBCscatter e

Determination of microcystins in fish tissues - ResearchGate

Crude extracts were filtered using GHP Acrodisc minispike filters and these were then analyzed using the HPLC method with diode array detection at 238 nm according to Jurczak et al. (2005).

MilliporeSigma | United States - Sigma-Aldrich

MilliporeSigma. Our purpose is to solve the toughest problems in life science by collaborating with the global scientific community – and through that, we aim to accelerate access to better health for people everywhere. We provide scientists and engineers with best-in-class lab materials, technologies and services.

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.