Female Luer-Lok inlet and standard male slip Luer outlet. Sterile. Modified acrylic housing. 75/pk. 1.5. $185.14. 4618. Acrodisc Syringe Filter with Supor Membrane Green. 0.8um pore size. 25mm diameter. For biological research. Polyethersulfone membrane provides high throughput and fast flow rate. Female Luer-Lok inlet and standard male slip
in the following direction only: from the female luer inlet to which the syringe is attached to the male luer slip outlet. Note 1. If you would like to achieve maximum recovery of your sample to be filtered, detach the syringe from the syringe filter and draw air once more into the syringe. After reconnecting
Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet . Typical Hold-Up Volume (with air purge) < 50 μL . Maximum Operating Temperature 55 °C (131 °F) Maximum Operating Pressure 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate 60 mL/min at 2.1 bar (210 kPa, 30 psi) Endotoxin Level
Female Luer-Lok Male Cuer slip - ml- Housing Material Membrane Materials Pore size of Membrane Inlet Fittings Outlet Fittings Process Volume Hold-up Volume(after air purge) Maximum Operating Pressure Maximum Operating Temperature Ordering Information < 250 10 bar (1 45psi) 45DC Units/Pk Pore Size (um) 0.22 0.45 0.22 0.45 0.22 0.45 Hydrophobicity
PVDF (Polyvinylidene difluoride) syringe filters are designed for HPLC and GC sample prep/clean up and protein-based samples with high non-specific binding. PVDF is a broad purpose hydrophobic membrane that can be used in a variety of applications. Polypropylene housing with female Luer-lock inlet and male Luer slip outlet.
Sample Volume < 150 mL. Inlet/Outlet Connections. Female threaded luer inlet, male slip luer outlet. Acrodisc Syringe Filters with GHP membrane. 0 500 1000 1500 ...
Volume throughput up to 2 ml up to 10 ml up to 100 ml up to 100 ml Inlet connection Female Luer lock Female Luer lock Female Luer lock Female Luer lock Outlet connection Male Luer/tube tip Male Luer/tube tip Male Luer Male Luer/Luer lock Sterilization§ Autoclave at 121°C Autoclave at 121°C Autoclave at 121°C Autoclaving not recommended
Excellent for small-volume assays such as EIA and ELISA. Cellulose acetate membrane is low protein binding with low extractables. Membrane diameter: 4mm. Sample volume size: 0.5–1.0mL. Polypropylene housing. Inlet: female Luer-lock. Outlet: male Luer slip. Nonsterile
membrane filters 7 membrane types Female Luer-Lock inlet, male Luer-slip outlet Solvent resistant polypropylene housings PES, GMF, Polypropylene and Cellulose Acetate membranes are certified for Ion Chromatography The polypropylene housings with all Target syringe filters
Outlet connection Minispike Male Luer Typical hold-up volume (with air purge) <14 uL <100 uL Pore size and part number 0.2 µm 4554 0.2 µm 4564 0.45 µm 4556 0.45 µm 4560 Packaging 100/pkg, 300/case 50/pkg, 200/case While other filters will only work well with one or two types of solutions, the GH Polypro membrane is effective
small-volume (10 to 100 mL) filtration. Accepts 25 mm filter discs. Luer inlet and outlet fittings provide easy connections. Delrin (acetal resin) construction provides broad chemical compatibility and material strength. Pall Laboratory products are designed for laboratory
Female Luer Lock inlet and Male Luer slip outlet Membrane Solutions Sterile PES Syringe Filters 0.22um Pore Size, 33mm Membrane Diameter MS sterile syringe filters are made with a wide variety of membrane filters with polypropylene (PP) housing, using the most advanced methods and design features.
Inlet/Outlet Connections Female threaded luer inlet, male slip luer outlet AU T OM I N CERTIFIED ® AND Typical Hold-Up Maximum Maximum Typical Part Pore Volume Operating Operating Water Number Description Size (w/air purge) Temperature Pressure Flow Rate AP-4305 GxF/GHP 0.2 µm < 200 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi
Aijiren Tech Scientific - Pall Universal membrane syringe filters for all of your analytical filtration requirements. Shop Pall Acrodisc™ Syringe Filters with PTFE Membrane Pall Acrodisc™ Syringe Filters with PTFE Membrane and Male Slip Luer Outlet 0.2 μm; 1000/Pk.
Luer-slip Syringe (6) Pipet Pump Male Luer-lok Hub Adapter (1) Male Luer-lok Hub Adapter, for 10 to 33 ga. Needles ... Multi-sample Luer Adaptor (1) Needle ...