Inlet/Outlet Connections 13 and 25 mm: Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume (with air purge) 13 mm: < 15 µL 25 mm: < 125 µL 25 mm prefilter: < 150 µL Maximum Operating Temperature 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 13 mm: 6.9 bar (690 kPa, 100 psi)
Housing: Polypropylene Pore Size 0.2 μm Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet Membrane Bed Volume 0.12 mL Maximum Operating Temperature and Pressure 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical Differential Pressure < 0.07 bar (7 kPa, 1 psi) @ 1 mL/min
Housing: Polypropylene; Effective Filtration Area. 2.8 cm 2; Inlet/Outlet Connections. Female luer lock inlet, male slip luer outlet; Typical Hold-Up Volume (with air purge) < 50 μL; Maximum Operating Temperature. 55 °C (131 °F) Maximum Operating Pressure. 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate. 60 mL/min at 2.1 bar (210 kPa, 30
Luer fittings are available in 100% virgin raw materials, plastic and specialty plastic, and metal. Premium raw material luer fittings are free of contaminants and ideal for syringes or small tubing. Plastic luer assemblies and specialty plastic luer fittings are designed for many applications with small tubing.
male slip luer outlet (1/4-1/2 in.) diameter with female slip luer ID in the hose barb Typical Hold-up Volume – < 100 µL < 2.5 mL (with Air Purge) Maximum Operating Temperature* – 60 ºC (140 ºF) at 2.1 bar 60 ºC (140 ºF) at 1.0 bar
Polypropylene Polypropylene Polypropylene Filtration area 0.125 cm2 1.6 cm2 4.9 cm2 0.125 cm2 1.6 cm2 4.9 cm2 Maximum pressure 5.5 BAR 8 BAR 15 BAR 5.5 BAR 8 BAR 10 BAR Residual volume < 15 µL with air purge < 35 µL with air purge < 157 µL with air purge < 15 µL with air purge < 35 µL with air purge < 157 µL with air purge
Housing: Polypropylene Effective Filtration Area 2.8 cm2 Inlet/Outlet Connections Female luer-lok inlet, male slip luer outlet Typical Hold-up Volume (with air purge) < 50 µL Maximum Operating Temperature 55 °C (131 °F) Maximum Operating Pressure 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate 60 mL/min at 2.1 bar (210 kPa, 30 psi)
Maximum reverse differential pressure: 30 PSID (2.1 bar) at 68°F (20° C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PV C: 122 °F/50 Regulatory Compliance The discs are manufactured from materials that conform to the require-ments of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and
Max. operating pressure: 13mm: 3.5 bar (350 kPa, 50 psi) 25mm: 15mL/min at 3.1 bar: Male slip luer outlet: $266.76 100/PK: ... 144mL/min at 2.1 bar ...
Maximum operating pressure is 101 psi. Model 29550-44 has hose nipples which can be replaced by luer connectors to use it as a large-area syringe filter holder. 29550-44 Dia Filtration area Connection Catalog number Qty/ pk Price/ pk 13 mm 0.5 cm2 Female luer lock inlet, luer slip outlet GH-29550-40 12 assembly/disassembly of PFA filter holders
Pore Size (µm) psi bar psi bar 0.2 13 0.9 30 2.1 0.45 5 0.3 — — 130.2—— 1. Fill a 10 mL syringe* (male luer) with water. 2. By using a 3-way connector, attach the syringe pressure gauge (must measure up to 30 psi, 2.1 bar, 210 kPa), syringe, and the external connector of the Acro 50 vent filter. 3. Gently fill the housing and
30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 44 psid (3.0 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 45 kGy 45 kGy Gamma Stablized PP She l Maximum reverse differential pressure: Maximum gamma irradiation resistance: Operating Conditions HD PE VC Maximum working pressure @ 77°F/25°C: Minimum burst
Connections Female Luer-Lok™ inlet, male Luer-slip outlet Pressure limit at 21 °C 8.6 bar (125 psi) differential Filtration volume 10–100 mL Hold-up volume ≤ 80 µL after air purge at pressure that exceeds bubble point of the membrane Performance Membrane Type Typical Water Flow Rate at 21 °C and 2.1 bar (30 psi) Bubble point
Filter Media: Mustang E membrane Housing: Polypropylene Pore Size 0.2 µm Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet Membrane Bed Volume 0.12 mL Maximum Operating Temperature and Pressure 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical Differential Pressure
Inlet/Outlet Connections 13, 17, 25 & 31mm: Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume (with air purge) 13 mm: < 15 μL 17mm : < 18 μL 25 mm: < 80 μL 25 mm Prefilter: < 80 μL 31 mm: < 80 μL Maximum Operating Temperature 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 13 mm: 6.9 bar (690 kPa