Home » News » GHP Filter » luer lock pall ghp maximum operating pressure 2.1 bar

luer lock pall ghp maximum operating pressure 2.1 bar

Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock – MACCA0507. €55,00. Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock – MACCA...
Product Introduction

Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock

Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock – MACCA0507. €55,00. Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock – MACCA0507 is an original Pall ® 5 micron solvent and UV capsule filter with Luer Lock connection. IN STOCK. Pall ® Ink Jet and UV Capsule Filter 5 micron Luer Lock – MACCA0507 quantity.

GHP Discontinuation - Accessories Spare Parts - Pall Corporation

Nov 01, 2019 · 1. Free Ground Shipping (Shipping Discount) is applied to selected products only. 2. This discount expires on the 31 st December 2021.. 3. This discount applies to online credit card orders only from shop.pall.com.

Iso9001 ghp syringe filter maximum operating pressure 2.1 bar

Pall's GHP media is a “universal” membrane that can be Acrodisc syringe filters with Supor® membrane, sterile 2.1 bar (210 kPa, 30 psi) at 60 °C.

male slip luer outlet ghp filters maximum operating

Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume (with air purge) . 125 µL Maximum Operating Temperature 82 °C (180 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 4.1 bar (410 kPa, 60 psi) at 21 - 24 ºC (70 - 75 ºF) 2.1 bar (210 kPa, 30 psi) at 82 ºC (180 ºF) Typical Water Flow Rate

male slip luer outlet ghp membrane maximum operating pressure

[4554] Acrodisc Syringe Filter with GHP Membrane 13mm 0.2 um . The "Universal" Membrane Filter for All of Your Analytical Filtration Requirements 25 mm PSF: Female luer lok inlet, male slip luer outlet. polypropylene housing ghp membrane lower hold-up volume

Luer Lock Filter at Thomas Scientific

Denville Syringe Filters are easy to use. They may be used with any luer-lock syringe and are color-coded for easy recognition. The 30mm syringe filters can filter up to 100mL of sample with a retention volume of less than 100µL. The 13mm filters can filter 5 to 10mL of sample and have. Related Products: 0.22 Pes.

Luer Fittings from Cole-Parmer

Masterflex® Adapter Fittings, Female Luer to Hose Barb, Straight, P. $16.60 - $27.25USD / Pkg of 25. View All 9. View Items to Compare. Masterflex® Adapter Fittings, Male Luer to Hose Barb, Straight, P. $14.30 - $23.25USD / Pkg of 25. View All 19. View Items to Compare.

luer lock ghp membrane filter maximum operating pressure 2.1

13, 17, 25 & 31mm: Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume (with air purge) 13 mm: 15 μL 17mm : 18 μL 25 mm: 80 μL 25 mm Prefilter: 80 μL 31 mm: 80 μL Maximum Operating Temperature 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 13 mm: 6.9 bar (690 kPa, 100 psi) 17 mm: 130 psi

Acrodisc® PSF Syringe Filters - pall.com

Female threaded luer inlet, male slip luer outlet AU T OM I N CERTIFIED ® AND Typical Hold-Up Maximum Maximum Typical Part Pore Volume Operating Operating Water Number Description Size (w/air purge) Temperature Pressure Flow Rate AP-4305 GxF/GHP 0.2 µm < 200 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 175 mL/min at 2.1 bar

Gardian™ 100 High Pressure Filter - Pall Shop

Manufactured using a modified acrylic housing material, this next generation filter is designed to withstand higher operating pressures and exposure to alcohols. With its advanced sealing technology and the proven drug compatibility of Supor PES membrane, this new Pall filter delivers an increased level of patient safety and protection. New

Stax™ mAx Clarification Platform - Pall Shop

Maximum Operating Pressure: 3 bar (44 psi) at 40 °C: 3 bar (44 psi) at 40 °C: 3.5 bar (50 psi) at 25 ºC 1.0 bar (14.3 psi) at 60 ºC: Maximum Differential Pressure: 1.5 bar (22 psi) 1.5 bar (22 psi) 2.4 bar (35 psi) at 25 ºC: Maximum Operating Temperature: 40 °C: 40 °C: 60 °C: Sterilization Autoclaving: 1 x 30 minute at 125 °C: 1 x 60

polypropylene housing pall ghp maximum operating pressure 2.1 bar

Housing: Polypropylene Effective Filtration Area 2.8 cm2 Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume (with air purge) 50 µL Maximum Operating Temperature 55 °C (131 °F) Maximum Operating Pressure 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate 60 mL/min at 2.1 bar (210 kPa, 30 psi Pall 4558 Acrodisc Syringe Filters with GHP Membrane Pack of

Certified ghp membrane maximum operating pressure 2.1 bar

Certified ghp membrane maximum operating pressure 2.1 bar GH Polypro (GHP) Membrane Disc Filters – Separations Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point – Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 k

High Pressure Tubing Line, Female Luer Lock, Male - Qosina

33003. Qosina offers an extensive line of pre-assembled extension lines available in a variety of configurations that are in stock and ready for immediate delivery. Qosina part # 33003 is a high pressure extension line which features a female luer lock on one tube end and a male luer lock connector on the other.

Cembre RHTD3241T Cembre优势供应_电工电气栏目_机电之家网

Cembre牌的Cembre HT-TC026 手动液压切刀产品:估价:0,规格:HT-TC026,产品系列编号:15350459371

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.