Female luer lock inlet, male slip luer outlet; Typical Hold-Up Volume (with air purge): 13 mm: <30 μL; 25 mm PSF: <125 μL; Maximum Operating Temperature: 13 mm: 55°C (131°F) 25 mm PSF: 100°C (212°F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure: 13 mm: 6.9 bar (690 kPa, 100 psi)
Female luer lock inlet, male slip luer outlet; Typical Hold-Up Volume (with air purge): 13 mm: <30 μL; 25 mm PSF: <125 μL; Maximum Operating Temperature: 13 mm: 55°C (131°F) 25 mm PSF: 100°C (212°F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure: 13 mm: 6.9 bar (690 kPa, 100 psi)
Pall Acrodisc Syringe Filters with Supor Membrane Female luer lock ... 70uL 32 and 37 mm:<100 uL Maximum Operating Temperature 55 °C (131 ...
Supor hydrophilic polyethersulfone membrane filter offers superior flow rates. Modified acrylic housing with female Luer lock inlet and male slip Luer outlet. Maximum operating temperature 55°C (131°F). Passes USP Class VI - 121°C plastic tests. Sterilized by gamma irradiation and individually packed. Other products by Pall Gelman
Maximum operating temperature: 55°C (131°F). Fluid retention for 25mm filters is less than 40µL with air purge. Male Luer slip and female Luer-lock connections. Modified acrylic housing. Certified nonpyrogenic. Other products by Pall Gelman More Information
Maximum operating temperature 55°C. Pressure 5.2 bar (520 kPa, 75 psi). Acrodisc PF and Serum Acrodisc syringe filters feature built-in prefilter for increased throughput of difficult-to-filter liquids. Sterile Acrodiscs are constructed of modified acrylic with a female luer lock inlet and a male slip luer outlet. Packaged in individual
Acrodisc® Syringe Filter with Luer-lock design facilitates use with syringes. Versapor® (acrylic copolymer) membrane filters feature large pore sizes ideal for prefiltration. Filters withstand normal syringe pressures up to 75psi. Maximum operating temperature for 25mm sizes 55°C. Color-coded by pore size for easy identification.
Luer-lock design facilitates use with syringes. Versapor® (acrylic copolymer) membrane filters feature large pore sizes ideal for prefiltration. Filters withstand normal syringe pressures up to 75psi. Maximum operating temperature for 25mm sizes: 55°C Sold as a pack of 50 STERILE blister packed filters. PALL 4190
Acrodisc Syringe Filters with PTFE Membrane, 13 mm 4423 0.2 µm, male slip luer outlet 100/pkg 300/cs NA 0 4542 0.2 µm, male slip luer outlet 1000/pkg NA 0 4422 0.45 µm, male slip luer outlet 100/pkg 300/cs NA 0 4543 0.45 µm, male slip luer outlet 1000/pkg NA 0 Zymark* and SOTAX* Automation Certified Acrodisc PSF Syringe Filters With PTFE
Acrodisc Housing: 13 mm: Polypropylene 25 and 32 mm: Modified acrylic 37 mm: Polypropylene Serum Acrodisc Housing: ABS Pore Size 0.1, 0.2, 0.45, 0.8, 1.2, and 5 µm Effective Filtration Area 13 mm: 1.0 cm2 25 mm: 2.8 cm2 32 mm: 5.8 cm2 37 mm: 7.5 cm2 Inlet/Outlet Connections Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume
design For prefiltration Luer-lock design facilitates use with syringes. Versapor® (acrylic copolymer) membrane filters feature large pore sizes ideal for prefiltration. Filters withstand normal syringe pressures up to 75psi. Maximum operating temperature for 4mm size: 88°C;
Male Luer slip and female Luer-lock. Filter. 0.2 micron. Sterile. Yes. Suitable for filter sterilizing dilute biological fluids. Low hold-up volume minimizes sample loss. HT Tuffryn (polysulfone) membrane is extremely low protein-binding. Maximum operating temperature: 55°C (131°F).
Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume (with air purge) 13 mm: < 28 µL 25 mm: < 70 µL 32 and 37 mm: < 100 µL Maximum Operating Temperature 55 °C (131 °F) Maximum Operating Pressure 5.2 bar (520 kPa, 75 psi) Typical Water Flow Rate mL/min at 3.1 bar (310 kPa, 45 psi) 0.1 μm, 25 mm: 35 0.1 μm, 32 mm: 100 0.2
Features: SPECIFICATION: Pore Size: 5 µm, Filter Size 32 mm, Effective Filtration Area (Metric): 5.8 cm² and Hold-Up Volume . 100ul, Maximum Operating Temperature 55 °C and Maximum Operating Pressure 5.2 bar. Membrane Material Supor (Hydrophilic polyethersulfone) Connector: Inlet/Outlet Connections Female Luer lock inlet, male slip Luer outlet.
Connect with female luer lock at inlet and standard male slip luer on the outlet. Maximum temperature is 131 0 F ( 55 0 C). Maximum operating pressure is 75 psi (5.2 bar). Warning: This product is not approved or intended for, and should not be used for medical, clinical, surgical or other patient oriented applications.