Millex® Syringe Filters - Sigma-Aldrich. Fast flow and low binding for cell culture media preparation with Millipore Express ® PLUS polyethersulfone (PES) membrane; Durapore ® PVDF membrane is the lowest binding membrane for protein-rich solutions; Many are CE-marked and/or approved as medical devices, meaning that they can be used to filter pharmaceutical solutions
Low protein binding membrane gives high recovery of critical proteinaceous samples. Accurate analysis. HPLC certified for low levels of UV-absorbing extractables. Easy filtration of particulate-laden samples with glass fiber prefilter version. 13 mm Acrodisc syringe filter with minispike configuration offers low hold-up and easy filtration into
4566 - GHP Membrane - Acrodisc Syringe Filters, 25mm, Pall "These syringe filters offer a choice of filter media: hydrophobic PTFE membrane for exceptional chemical and temperature compatibility -hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without prewetting -GHP (hydrophilic polypropylene) membrane for low protein binding -and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous
GH Polypro (GHP) Membrane Disc Filters - Separations. Low protein binding membrane gives high recovery of critical proteinaceous samples. HPLC certified. Provides assurance that the filter will not add artifacts to. Pall GH Polypro (GHP) Membrane Disc Filters, 66557, 66628
Cellulose Acetate (CA) is a great material for filtering aqueous and alcoholic media, especially hot liquids and gases because it offers high flow rates and thermal stability yet low absorption. High physical strength for high viscosity filtration and separation. Great for aqueous protein solutions because it's low protein binding.
33mm Syringe Filter Parameters 33mm Effective Filtration Area(cm2)5.39Holdup volume (μl)200Maximum Pressure87psi (6.0 bar) at 20 °CSample volume (ml)200Maximum Operating Temperature50 °CConnectorsnlet: Female Luer Lo. Contact Now 13mm Syringe Filter Parameters 13mm Effective Filtration Area(cm2)1.09Materials of ConstructionHousing:PPMaximum
33mm Syringe Filter Parameters 33mm Effective Filtration Area(cm2)5.39Holdup volume (μl)200Maximum Pressure87psi (6.0 bar) at 20 °CSample volume (ml)200Maximum Operating Temperature50 °CConnectorsnlet: Female Luer Lo. Contact Now 13mm Syringe Filter Parameters 13mm Effective Filtration Area(cm2)1.09Materials of ConstructionHousing:PPMaximum
GHP membrane also has an extremely low autofluorescence Polypropylene. Effective Filtration Area. 0.3 cm2. Dimensions. HPLC and Chromatography Sample Prep - VWR. Acrodisc PSF GxF syringe filters with glass/GHP membrane Effective Filtration Area. 3.9 cm2. Inlet/Outlet Connections. Female luer lock inlet, male slip. Syringe Filters - Pall Shop
polypropylene housing ghp membrane lower hold-up volume . 0.45um GHP hydrophilic polypropylene membrane for chemical compatibility fast flow rates low protein binding low levels of UV-absorbing extractables. HPLC and Chromatography Sample Prep - VWR. A filter with a low hold-up volume is recommended for Low protein binding membrane GHP Membrane is Extremely Low in Biomolecule Binding.
28139-550CS 894.3 USD. 28139-550 28139-548 28143-264. Acrodisc® Syringe Filters with GHP Membrane, Pall Laboratory. Filters Syringe Filters. Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including syringe filters, filter plates, centrifugal devices and membrane filter discs.
Pall Laboratory. of filter media: hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without pre-wetting; GHP (hydrophilic polypropylene) membrane for low protein binding; and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and non-aggressive,. Compare this item.
Filter Media: Glass Fiber / GH Polypro membrane (GHP, hydrophilic polypropylene) · Housing: Polypropylene · Type: Syringe Filter · Use: Particulate Filter, High Quality Specialty Syringe Filters | I.W. Tremont. This membrane is recommended for all filtrations in aqueous or polar media, bacteria filtration Very low binding capacity for proteins. Ghp Membrane at Thomas Scientific
Description. Supor EKV filters are 0.2 micron rated validated sterilizing-grade membrane filters. The incorporated PES membrane demonstrates very high compatibility over the whole pH range plus very low protein binding to ensure the maximum transmission of the active ingredients. The Mini Kleenpak capsule format is designed for use in the
Acrodisc® Syringe Filters. Pall Laboratory. of filter media: hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without pre-wetting; GHP (hydrophilic polypropylene) membrane for low protein binding; and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and non-aggressive,.
Acrodisc® PSF Syringe Filters - Pall Shopcopolymer on a non-woven support) membranes. GxF Prefilter: Borosilicate glass. Housings: Polypropylene. Effective Filtration Area. 3.9 cm