Home » News » GHP Filter » low protein binding membrane ghp membrane supplier

low protein binding membrane ghp membrane supplier

Naturally Occurring Variants in LRP1 (Low-Density Lipoprotein Since its discovery in 1988 through homology cloning with the LDL (low-density lipoprotein) receptor, the LRP1 (LDL receptor–related p...
Product Introduction

Naturally Occurring Variants in LRP1 (Low-Density Lipoprotein

Since its discovery in 1988 through homology cloning with the LDL (low-density lipoprotein) receptor, the LRP1 (LDL receptor–related protein 1) has been considered an important regulator of plasma lipid concentrations by its effect on the clearance of atherogenic triglyceride-rich lipoproteins. 1,2 LRP1 is also recognized for its role in other biological processes, including homeostasis of

Pall Laboratory | VWR

Learn more about Pall Laboratory. We enable science by offering product choice, services, process excellence and our people make it happen.

Pall Nanosep ® MF Centrifugal Device with GHP Membrane

The GH Polypro hydrophilic polypropylene membrane is ideal for aqueous solutions and offers maximum chemical compatibility for aggressive solvents. 96.5% protein recovery. GH Polypro membrane is a low protein binding membrane. It removes unwanted particulate from samples with high recovery of critical proteins.

GH Polypro (GHP) Membrane Disc Filters - Separations

GH Polypro (GHP) Membrane Disc Filters All purpose, universal membrane with maximum chemical compatibility for both aqueous solutions and aggressive solvents Specifications Filter Media Hydrophilic polypropylene Pore Size 0.2 and 0.45 µm Typical Thickness 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) Typical Water Flow Rate mL/min

Pall Nanosep ® MF Centrifugal Device with GHP Membrane

The GH Polypro hydrophilic polypropylene membrane is ideal for aqueous solutions and offers maximum chemical compatibility for aggressive solvents. 96.5% protein recovery. GH Polypro membrane is a low protein binding membrane. It removes unwanted particulate from samples with high recovery of critical proteins.

Acrodisc® syringe filters GHP membrane, diam. 25 mm, pore

Acrodisc® syringe filters GHP membrane, diam. 25 mm, pore size 0.45 μm; find -Z259845 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich

Acroprep™ Filter Plates with GHP Membrane, Pall - VWR

Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including Filter Plates, Syringe Filters, Centrifugal Devices and Membrane Filter Discs. Essential for biomolecule purifications and separations filter plates are offered in different filtration media membrane to accommodate any array applications. With individual membranes

Centrifugal Devices - Pall Corporation

and low non-specific protein and nucleic acid binding. Add versatility – Available in various membrane types including low-binding Bio-Inert ® (modified nylon), Supor ® (polyethersulfone), and GHP (polypropylene) membranes, as well as Omega™ (modified polyethersulfone) ultrafiltration membrane in a variety of MWCOs.

unlaminated teflon mushroom syringe filter China-HPLC Vial

Acrodisc mushroom syringe filter whosales-HPLC Vial Inserts unlaminated 0.22 um PTFE syringe filter Acrodisc-Analytical Oct 29, 2021 · Acrodisc® syringe filters PVDF membrane, diam. 13 mm, pore Acrodisc® syringe filters PVDF membrane, diam. 13 mm, pore size 0.2 μm; find -Z260282 MSDS, related peer-reviewed papers

ghp membrane filter low protein binding membrane exporter

The GHP membrane used in Pall Laboratory Acrodisc® syringe filters, centrifugal devices due to the rationalization of a key material from our supplier. Acrodisc PSF GxF Syr. Filters, GHP Membrane, 25 mm AP4559. Versatile filter for aqueous and aggressive organic solvent-based solutions. Low protein binding membrane gives high recovery of

Acrodisc® syringe filters GHP membrane, diam - Sigma-Aldrich

General description. These offer high quality filtration for analytical samples. Certified for HPLC to ensure low extractables. Available in a broad range of membranes to meet sample compatibility requirements. The 25 mm Acrodisc is recommended for sample volumes from 5 to 100 mL. The 13 mm size is recommended for samples under 10 mL in volume.

Nanosep® MF Centrifugal Devices with GHP Membrane

Currently this quote has no items. Cart 0. Ihr Warenkorb ist leer.

Ghp Membrane at Thomas Scientific

Pall Laboratory. of filter media: hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without pre-wetting; GHP (hydrophilic polypropylene) membrane for low protein binding; and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and non-aggressive,. Compare this item.

low protein binding membrane ghp membrane filter supplier

Features: Low protein binding membrane gives high recovery of critical proteinaceous samples. Accurate analysis. HPLC certified for low levels of UV-absorbing extractables. Easy filtration of particulate-laden samples with glass fiber prefilter version. 13 mm Acrodisc syringe filter with minispike configuration offers low hold-up and easy

Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life

Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences is a reliable and dependable addition to the Pall Filters family of products. Combining top-notch and uncompromising quality with an affordable price, the Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences 66548/ 28143-288 can fulfill your laboratory needs while still offering a great value for the money.

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.