Jun 20, 2013 · Maximum Operating Temperature : 55 °C (131 °F) Minimum Bubble Point - Water - 0.2 μm: 2.9 bar (290 kPa, 42 psi) - 0.45 μm: 1.38 bar (138 kPa, 20 psi) Performance. GH Polypro (GHP) Membrane is Virtually a Universal Membrane for All Applications
Types of polypropylene plates: - Chamber; - Membrane with a fixed membrane; - Membrane with a removable membrane. Typical range of polypropylene plates: from 250х250 mm to 2000 х2000 mm. Sediment thickness: from 20 to 60 mm. Maximum working pressure: up to 3,5 MPa. Maximum Operating Temperature: 90 °С.
10K Ultrafiltration Membrane OPERATING LIMITS Maximum operating pressure 140 psi (9.7 bar) Maximum operating temperature 131°F (55°C) Maximum cleaning temperature 122°F (50°C) Acceptable operating pH range 2.5–10.0 Acceptable short-term cleaning pH range 1.7–11.5 Maximum pressure drop per element 15 psi (1.0 bar)
Filter Media Hydrophilic PVDF Membrane Drainage Layers Polyester Housing Polypropylene Differential Pressure < 4Kg/cm ²at 30 °C Maximum Operating Temperature 80 °C @ < 2 Kg/cm ² Sterilization Pre sterilized by Gamma Irradiation LOT RELEASE CRITERIA
Acrodisc® Syringe Filter with wwPTFE membrane & wwPTFE Membrane Disc Filters, Pall. Avoid the expense and inconvenience of keeping a variety of filters on hand. Versatile filter for aqueous and aggressive organic solvent-based solutions. AutoPack™ packaging is easy to use and the Automation Preferred™ certification assures you of smooth
Product Description. Hi-Tech 4021 RO membrane elements is made by the most advance technique polyamide RO membrane sheets and combined with experience on the process of rolling membranes for years. Hi-Tech membrane performance is excellent and stable exceptionally. Covering a complete range from 50GPD to 400GPD. Hi-Tech Membrane BW30 – 400.
Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point - Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 kPa, 20 psi) Maximum versatility. Filters aqueous solutions or aggressive chemicals. Low protein binding membrane gives high recovery of critical proteinaceous samples. HPLC certified. Provides assurance
GH Polypro membrane is the best choice for filtering mobile phases Maximum Operating Temperature (Metric) 55 C ... Maximum Operating Temperature. wwPTFE Membrane ...
Membrane: Polyethersulfone Support layers: Polypropylene Structure: Polypropylene All components are thermally bonded to ensure integrity and to reduce extractables. Effective Filtration Area 6.8ft2 ± 0.3ft2 / 0.63m2 ± 0.0279m2 per 10" (250mm) cartridge Maximum Differential Pressure/ Temperature Forward: 80psid (5.5bar) @ 75ºF (24ºC)
Description. Product Description. Hi-Tech BW30-4040 Industrial RO membrane elements is made by the most advance technique polyamide RO membrane sheets and combined with experience on the process of rolling membranes for years. Hi-Tech membrane performance is excellent and stable exceptionally. Covering a complete range from 50GPD to 400GPD.
Polypropylene General Properties English Units SI Units Shore D Scale 55 – 65 55 – 65 ... Vicat Softening Temperature Homopolymer 305 °F 152 °C Copolymer ...
Materials PTFE membrane filter, strengthened with polypropylene gauze. Polypropylene housing Limits Max. recommended operating pressure, 3 bar (300 kPa). Max. temperature, 134°C Sterilization By autoclaving at 121°C (at least 20 times) or 134°C. The E and G packs are presterilized with ethylene oxide Priming volume Approx. 3 ml
OPERATING LIMITS Maximum operating pressure 140 psi (9.7 bar) Maximum operating temperature 131°F (55°C) Maximum cleaning temperature 122°F (50°C) Acceptable operating pH range 2.5–10.0 Acceptable short-term cleaning pH range 1.7–11.5 Maximum pressure drop per element 15 psi (1.0 bar) Maximum pressure drop per vessel 60 psi (4.1 bar)
Membrane Filters - GH Polypro Disc, Pall Gelman. SKU. 12-4611. Add to Wish List. Email to a friend. Maximum operating temperature 55°C (131°F). More Information
Membrane Diameter: 30 mm Effective Filtration Area: 4.8 cm 2 Housing Diameter: 33 mm Housing Material: Pure polypropylene is heat-sealed without the use of glues or sealants Inlet / Outlet: FLL-MLS Prefilter: 1.0 μ binderless glass-fiber, in some configurations Holdup Volume: <90 microliter Maximum Operating Temperature: 82°C/180°F