Membrane Polyethylene (PE) Molded Components (shell) Polyethylene (PE) Measurements (nominal) Size Outside Diameter (mm) Body Length Without Fittings (mm) Filtration Area (cm2) D13R 16 3.7 0.8 D25C 33 5.45 4.6 D40C 45.5 8 10.5 Operating Conditions Maximum Temperature 60 °C Maximum Inlet Pressure (at 22 °C) 2.1 bar | 30 psi
Operating Conditions Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C in m uB rst P res : 8.3 b a(1 20psi) t 7 °F/ 5 C Maximum Forward Di˝erential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Di˝erential Pressure: 2.1 bar (30psi) at 68°F/20°C
Hydrophobic PTFE Hold-Up Volume <125 µL Housing Material Polypropylene Maximum Operating Pressure (bar) 2.1 bar Maximum Operating Temperature (Metric) 100 °C Typical Flow Rate 510 mL/min at 1.0 bar (100 kPa, 15 psi) Overview Description Type Use Documents Datasheets Download: English Description
typical hold-up maximum maximum typical part pore volume operating operating water number description size (w/air purge) temperature pressure flow rate ap-4305 gxf/ghp 0.2 µm < 200 µl 55 °c (131 °f) at 2.1 bar 4.1 bar (410 kpa, 60 psi) 175 ml/min at 2.1 bar ap-4307 (210 kpa, 30 psi) at 21-24 °c (70-75 °f) (210 kpa, 30 psi) ap-4306 ap-4557
Filter Media: Hydrophobic PTFE; Hold-Up Volume: 125 µL Housing Material: Polypropylene; Maximum Operating Pressure (bar): 2.1 bar; Maximum Operating Temperature (Metric): 100 °C; Pore Size (Removal Rating): 0.45 µm; Typical Flow Rate: 510 mL/min at 1.0 bar (100 kPa, 15 psi)
Maximum Operating Temperature 60 °C at 30 psi (2.1 bar) Sterilization 121 °C for multiple cycles at 15 psi (1.0 bar) Maximum Operating Pressure: 60 psi (4.1 bar) at ambient temperature : Minimum Bubble Point: 0.1 μm: 21 psi (1.5 bar) in ethanol 0.2 μm: 15 psi (1.1 bar) in ethano : Typical Water Flow Rate (after ethanol prewet) 0.1 μm:
75 psid @ 70°F (5.2 bar @ 21°C) 30 psid @ 176°F (2.1 bar @ 80°C) 15 psid @ 195°F (1.03 bar @ 95°C) Maximum reverse diff erential pressure: 40 psid @ 70°F (2.8 bar @ 21°C) Recommended change-out pressure: 35 psid (2.4 bar) GFPTFEV cartridge fi lters are constructed with naturally hydrophobic PTFE membrane and polypropylene support
Maximum Operating Pressure (bar) 2.1 bar Maximum Operating Temperature (Metric) 100 °C Quantity 50 pkg Typical Flow Rate 395 mL/min at 1.0 bar (100 kPa, 15 psi) Overview Description Type Description Syringe filters are used in analytical chemistry applications to remove particulate contamination prior to analysis.
Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Di˛erential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Di˛erential Pressure: 2.1 bar (30psi) at 68°F/20°C Maximum Operating Temperature: PP & Gamma PP
high operating pressures to avoid filter burst membrane for maximum chemical compatibility, AP-4307 2.1 bar at 21-24 °C (70-75 °F) at 2.1 bar ... GH Series High Pressure Compressed Air Filter (for pressures Maximum Flow Rate: 365 to 4261 (@350 barg) m3/hour, 214 @ 5076 psig to 2507 @ 5076 psig CFM.
Maximum Operating Temperature and Pressure 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical Differential Pressure < 0.07 bar (7 kPa, 1 psi) @ 1 mL/min Mean Flow Rate 1 - 4 mL/min; flow rate will vary with type of solutions, concentration of proteins, and other components
5.49 bar @ 21 °C (79.7 psid @ 70 °F) Recommended change-out pressure drop for disposal 2.1 bar @ 21 °C (30.5 psid @ 70 °F) Bubble point integrity test (absolute ethanol, 20°C ) 0.1 μm: ≥1.4 bar 0.22 μm: ≥1.0 bar 0.45 μm: ≥0.5 bar Feature-Tec’s EGCPT pleated membrane filter cartridges are made with a hydrophobic polytetraflu-
4. Apply appropriate pressure [2.1 bar (30 psi)] with syringe plunger and hold this pressure for 15 seconds. 5. Integrity of housing and membrane is proven by retention of water in the syringe, and by the pressure remaining steady. 6. If failure occurs, check connectors for leaks and repeat above steps. If failure reoccurs, discard filter unit. 7.
5.49 bar @ 21 °C (79.7 psid @ 70 °F) Recommended change-out pressure drop for disposal 2.1 bar @ 21 °C (30.5 psid @ 70 °F) Bubble point integrity test (absolute ethanol, 20°C ) 0.1 μm: ≥1.4 bar 0.22 μm: ≥1.0 bar 0.45 μm: ≥0.5 bar Feature-Tec’s EGCPT pleated membrane filter cartridges are made with a hydrophobic polytetraflu-
GH Polypro (GHP) Membrane Disc Filters All purpose, universal membrane with maximum chemical compatibility for both aqueous solutions and aggressive solvents Specifications Filter Media Hydrophilic polypropylene Pore Size 0.2 and 0.45 µm Typical Thickness 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) Typical Water Flow Rate mL/min