Home » News » GHP Filter » hydrophilic polypropylene ghp syringe filter maximum operating pressure 2.1 bar

hydrophilic polypropylene ghp syringe filter maximum operating pressure 2.1 bar

HPLC Mobile Phase Filtration Membranes – Pall Filter Media GH Polypro (GHP, hydrophilic polypropylene), TF (PTFE, hydrophobic polytetrafluoroethylene), PVDF (hydrophilic polyvinylidene fluori...
Product Introduction

HPLC Mobile Phase Filtration Membranes - Pall

Filter Media GH Polypro (GHP, hydrophilic polypropylene), TF (PTFE, hydrophobic polytetrafluoroethylene), PVDF (hydrophilic polyvinylidene fluoride), and Nylaflo™ (hydrophilic nylon) membranes Pore Size 0.2 and 0.45 µm Typical Thickness GHP Membrane 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) TF (PTFE) Membrane 0.2 µm: 139 µm

Acrodisc Syringe Filter PALL | High Performance Liquid

Acrodisc Syringe Filters with GHP Membrane (GHP, hydrophilic polypropylene) ... 55 C (131 F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 13 mm: 6.3 ...

Pall® Acrodisc® ion chromatography (IC) syringe filters

Maximum Operating Temperature: 13 mm: 55°C (131°F) 25 mm PSF: 100°C (212°F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure: 13 mm: 6.9 bar (690 kPa, 100 psi) 25 mm PSF: 4.1 bar (410 kPa, 60 psi) at 21-24°C (70-75°F); 2.1 bar (210 kPa, 30 psi) at 100°C (212°F) Typical Water Flow Rate: mL/min at 1.0 bar (100 kPa, 15 psi) 13 mm, 0

Acrodisc PSF Syringe Filters

Accurate pore size rating – Acrodisc PSF syringe filters are more retentive than standard 25 mm devices and are available with single-layer membranes or multilayer glass fiber prefilters.

STERILE SYRINGE FILTER

Maximum differential Pressure (reverse): 2.1 bar (30 Psi) @ 25 oC (77 oF) oMaximum Operating Temperature: 80 C (176 o F) Recommended Replacement Pressure: 2.4 bar (35.3 Psi)

Acrodisc® Syringe Filters Optimized for Scale Up

Maximum Operating Pressure 5.4 bar (540 kPa, 80 psi) at ambient temperature Typical Water Flow Rate mL/min at 2.1 bar (210 kPa, 30 psi) PN 4905: 130 PN 4906: 78 PN 4907: 130 PN 4908: 77 Recommended Integrity Test Minimum Bubble Point - Water PN 4905: 3.5 bar (350 kPa, 51 psi) PN 4906, 4908, and 4907: 3.2 bar (320 kPa, 46 psi)

Pall 4408TC ACRODISC Syringe Filter with PVDF Membrane

Filter Size: 25 cm²; Effective Filtration Area (Metric): 2.8 cm²; Filter Media: Hydrophilic polyvinylidene fluoride (PVDF) Hold-Up Volume: 100 µL; Housing Material: polypropylene; Maximum Operating Pressure (bar): 2.1 bar; Maximum Operating Temperature (Metric): 82 °C; Quantity: 50 pkg; Typical Flow Rate144 mL/min at 2.1 bar (210 kPa, 30 psi)

Pall 4501 Acrodisc Syringe Filters with PTFE Membrane, 25 mm

Filter Media: Hydrophobic PTFE; Hold-Up Volume: 125 µL Housing Material: Polypropylene; Maximum Operating Pressure (bar): 2.1 bar; Maximum Operating Temperature (Metric): 100 °C; Pore Size (Removal Rating): 0.45 µm; Typical Flow Rate: 510 mL/min at 1.0 bar (100 kPa, 15 psi)

PALL ACRODISC SYRINGE FILTERS - vgdusa.com

Acrodisc 25mm Premium Syringe Filter Polypropylene housing. GHP hydrophilic polypropylene membrane for maximum chemical compatibility fast flow rates low protein binding and low levels of UV-absorbing extractables. Pore size: 0.45um. Filtration area: 3.9cm2. Hold-up volume: \<125uL. 9. $2,249.72 AP-4564

Technical Guide Acrodisc Syringe Filters for Analytical

Burst/Pressure Test Acrodisc syringe filters are tested for resistance to pressure. This test is a quality and safety test to ensure the Acrodisc syringe filter housings will not rupture at their rated operating pressures. The maximum operating pressure listed in the product literature is well below the actual burst pressure.

Acrodisc PSF Syringe Filters - Medigene Sdn. Bhd.

of Acrodisc PSF syringe filters was collected and run • Available with GHP hydrophilic polypropylene ... AP-4307 2.1 bar at 21-24 °C (70-75 °F) at 2.1 bar ...

Acrodisc® PSF Syringe Filters

Filter Media: GHP (hydrophilic polypropylene), Nylon at 2.1 bar 4.1 bar (410 kPa, 60 psi) 175 mL/min at 2.1 bar ... Hold-Up Maximum Maximum Typical Part Pore ...

Syringe Filters - Ciro Manufacturing Corporation

Maximum Operating Temperature 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 13 mm: 6.9 bar (690 kPa, 100 psi) 17 mm: 130 psi 25 mm: 4.1 bar (410 kPa, 60 psi) at 21 - 24 ºC (70 - 75 ºF); 2.1 bar (210 kPa, 30 psi) at 55 ºC (131 ºF) Typical Water Flow Rate with Nylon membrane- mL/min at 2.1 bar (210 kPa, 30 psi)

Acrodisc® Syringe Filters with PVDF Membrane | Krackeler

Polypropylene syringe filters with a hydrophilic FP Vericel polyvinylidene difluoride (PVDF) membrane that wets out immediately and provides broad chemical and solvent compatibility. Designed to protect HPLC columns and instruments from particulate build-up and help eliminate spurious peaks.

Acrodisc wwPTFE Syringe Filters | Pall- MG Scientific

Acrodisc® Syringe Filter with wwPTFE membrane & wwPTFE Membrane Disc Filters, Pall. Avoid the expense and inconvenience of keeping a variety of filters on hand. Versatile filter for aqueous and aggressive organic solvent-based solutions. AutoPack™ packaging is easy to use and the Automation Preferred™ certification assures you of smooth

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.