The GHP membrane is compatible with acids and bases, as well as aggressive organic solvents and halogenated solvents. These unique characteristics of the GHP membrane allow the Acrodisc syringe filter to serve as a universal membrane for use across a wide range of sample prep applications.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types.
" These 13mm syringe filters are ideal for HPLC, IC (ion chromatography), and other analytical sample preparations. -Ideal for analytical separations -Polypropylene housing -Luer-lock inlet Small minispike outlet prevents âœair bubbleâ lock in autosampler vials and NMR tubes. For volumes up to 10mL.
Sterilization by filtration is a safe and convenient method to remove microorganisms from biological liquids, while minimizing the effects on the ingredients. Various available diameters (13, 25, 30mm): right size for the right volume or particulate load. Available with PES membrane: provides >98.5% percent protein recovery. Pre-sterilized: ready to use for sterile filtration and clarification of
Made of high-quality Polypropylene. Polypropylene housing. Various filtering cut-off particle sizes in the range of 0.22-10 µm. Filter diameter at 25 mm. Filtration area: 4.9 cm 2. Hydrophilic, applicable to aqueous solutions and almost all organic solutions. Double Luer Lock fitting syringes with various volumes. Non-sterile.
Combining top-notch and uncompromising quality with an affordable price, the Pall Acrodisc Syringe Filters, Glass Fiber, Pall Life Sciences GHP/Glass Fiber Membrane Filter 4558/ 28143-263 can fulfill your laboratory needs while still offering a great value for the money.
6.3.1 10- to 25-mL filter -adaptable syringe with luer lock: high density polyethylene (HDPE), polypropylene or glass (rubber tipped plungers are not to be used). 6.3.2 50-mL polypropylene tubes (BD Falcon, Catalog # 352098) 6.3.3 15-mL polypropylene tubes (BD Falcon, Catalog # 352097); use pre-
1. TEFIC Nylon66 syringe filters shell made of high-quality sanitary polypropylene material. 2. TEFIC Nylon66 syringe filters' precision design of the structure ensures smooth filtration, rationalization of internal space and low residual rate, reducing the waste of samples. 3. The edge part of our Nylon66 syringe filters with the thread, play
GHP (hydrophilic polypropylene) membrane is low protein binding. Both nylon and GHP membrane filters include a glass fiber prefilter layer, as well as being HPLC certified for low UV-absorbing extractables. The regular glass fiber membrane has very low extractables. Polypropylene housing. Female Luer-lock inlet and male slip Luer outlet.
Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including syringe filters, filter plates, centrifugal devices and membrane filter discs. Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered.
Feb 17, 2020 · Open the syringe package and remove the syringe needle. A syringe with a luer-lock tip is recommended. Syringe Volume depends on the samples to be filtered. Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a.
Product description. "These syringe filters offer a choice of filter media: hydrophobic PTFE membrane for exceptional chemical and temperature compatibility -hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without prewetting -GHP (hydrophilic polypropylene) membrane for low protein binding -and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and nonaggressive, solvent-based mobile phases.
This syringe filter is made with GHP (hydrophilic polypropylene) membrane for low protein binding and features a polypropylene housing with female Luer-lock inlet and standard male slip Luer outlet connections. The membrane is HPLC certified for low levels of UV-absorbing extractables. Membrane: GHP Membrane. Pore Size: 0.45 µm.
Male luer lock / <150 Female luer lock Enter from INLET 130 10 / YES Ultrasonic welding Female luer lock Male luer slip Enter from INLET 6 GF* Gamma Radiation* YES Over molding Female luer lock Male luer slip Enter from INLET 6 6XSHUSXUH PP 0.22, 0.45 & more 6 Gamma Radiation* 6LPSOHSXUH PP 0.22, 0.45 & more PP &KURPSXUH 0.22, 0.45 & more PTFE
Luer-Lock Syringe. VST. Luer-Lock Syringe. 10 mL Syringe for use with Syringe Filters to remove suspended solids from espresso and coffee samples. Can be flushed and re-used many times. High quality, B&D. Available bulk.