Ensuring the correct filtration membrane has been selected from different types of filter materials is often overlooked in routine laboratory sample filtration. Here, we explore different filtration properties and how to take a preventative—rather than reactive—approach, minimizing time spent troubleshooting and maximizing efficiency.
Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including syringe filters, filter plates, centrifugal devices and membrane filter discs. Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either
GHP has been at the cutting edge of food testing (microbiological and chemical), water testing, air quality and nutritional analysis in the UAE. Calibration Services GHP Calibration is ISO 17025: 2017- accredited by EIAC, thus providing commercial instrument calibration and test equipment repair services to the industry.
Aug 07, 2018 · To compare between all the common membranes and solvents, review the chemical compatibility chart in our guide to laboratory membrane filtration principles and chemical compatibility. You might also find it useful to follow our quick reference chart (below) or try our filter selector tool to find your membrane filter fast.
Pall® 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000 . Filter Media: Glass Fiber / GH Polypro membrane (GHP, hydrophilic polypropylene)
"These syringe filters offer a choice of filter media: hydrophobic PTFE membrane for exceptional chemical and temperature compatibility -hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without prewetting -GHP (hydrophilic polypropylene) membrane for low protein binding -and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous
Where to buy Eastman solvents. Please select a region and country for a list of authorized distributors. If a country is not listed for a region, contact Eastman for further information. Region: Select Region Asia Pacific Europe, Middle East & Africa Latin America North America. Country/Territory: Select Country.
Choice of filter media: hydrophobic PTFE membrane for exceptional chemical and temperature compatibility; hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, and no prewetting; GHP (hydrophilic polypropylene) membrane for low protein binding; and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and nonaggressive, solvent-based
GH Polypro (GHP) Membrane Disc Filters. All purpose, universal membrane with maximum chemical compatibility for both aqueous solutions and aggressive solvents. Specifications. Filter Media Hydrophilic polypropylene Pore Size 0.2 and 0.45 µm Typical Thickness 0.2 µm: 101 µm (4.0 mils) 0.45 µm: 114 µm (4.5 mils) Typical Water Flow Rate mL/min/cm2at 0.7 bar (70 kPa, 10 psi) 0.2 µm: 20 0.45 µm: 31 Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point - Water 0.2 µm: 2.9 bar
Universal membrane filter. The GH Polypro hydrophilic polypropylene membrane is ideal for aqueous solutions and offers maximum chemical compatibility for aggressive solvents. 96.5% protein recovery. GH Polypro membrane is a low protein binding membrane. It removes unwanted particulate from samples with high recovery of critical proteins.
Membrane disc filters, GH Polypro (GHP) Filters Membrane Filters. Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including Centrifugal Devices, Syringe Filters, Filter Plates, and Membrane Filter Discs. Download our application note under 'Related Items' below to see how
The GHP membrane used in Pall Laboratory Acrodisc® syringe filters, centrifugal devices and Acroprep™ filter plates will be discontinued due to the rationalization of a key material from our supplier. However we are excited to announce the launch of the NEW wwPTFE universal membrane as a direct replacement for GHP filtration products.
Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including Centrifugal Devices, Syringe Filters, Filter Plates, and Membrane Filter Discs.Filtre er vigtige i forskningslaboratorier og mange andre industrier for at fjerne partikler og skabe miljøer, der fremmer et bredt udvalg af eksperimenter og procedurer.
Shop Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences 66628, Pack of 100 | Be The First To Review Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences 66628, Pack of 100 + Free Shipping over $49.
PTFE membrane provides the ultimate in chemical compatibility for filtering harsh chemicals and HPLC mobile phases Application Purification and degassing of mobile phase solvents used in liquid chromatography applications Specifications Filter Media GH Polypro (GHP, hydrophilic polypropylene), TF (PTFE, hydrophobic polytetrafluoroethylene), PVDF