For difficult-to-filter samples with high particulates, such as soil samples, non-woven matrix filters provide heavy-duty fine filtration. Non-woven polypropylene (NWPP), for example, provides durability and high loading capacity for particulates. These non-woven matrices are generally thick pads with layered structures to minimize clogging.
GHP (hydrophilic polypropylene) membrane is low protein binding. Both nylon and GHP membrane filters include a glass fiber prefilter layer, as well as being HPLC certified for low UV-absorbing extractables. The regular glass fiber membrane has very low extractables. Polypropylene housing. Female luer lock inlet and male slip luer outlet.
Ghp Membrane at Thomas Scientific Acrodisc® Syringe Filters Pall Laboratory of filter media: hydrophilic nylon membrane for excellent chemical compatibility with esters, bases, and alcohols, without pre-wetting; GHP (hydrophilic polypropylene) membrane for low protein binding; and hydrophilic PVDF (polyvinylidine fluoride) membrane for use in aqueous and non-aggressive,
cause loss of significant amounts of biological materials due to unwanted protein binding with the membrane or introduce unexpected interferences to the samples from the syringe filter. Therefore, low protein binding and cleanliness are important features of a syringe filter’s performance. Polyethersulfone (PES) and polyvinylidene
Maximum versatility. Filters aqueous solutions or aggressive chemicals. Low protein binding membrane gives high recovery of critical proteinaceous samples. HPLC certified. Provides assurance that the filter will not add artifacts to your analysis. Applications Our number-one choice for filtering HPLC mobile phases.
GHP hydrophilic polypropylene membrane. Low protein binding. HPLC certified for low UV-absorbing extractables. Polypropylene housing has female Luer-Lok inlet and minispike outlet.\ 14uL hold-up volume. 100/pk 300/cs. $907.04. Pall Filter 4556. Minispike Acrodisc 13mm Syringe Filter 0.45um pore size. GHP hydrophilic polypropylene membrane.
Versatile – Available with GHP hydrophilic polypropylene membrane for maximum chemical compatibility, fast flow rates, low protein binding, and low levels of UV-absorbing extractables. Automation certiied – Designed to be fully compatible and reliable for use with the SOTAX u and Zymark u automated test systems. Acrodisc ® PSF Syringe Filters
low protein binding membrane ghp membrane exporter-Analytical Membrane Choices GHP acrodiscs® - Hydrophilic propylene c membrane suitable for aqueous, organic and has low protein binding. nylon acrodiscs - Hydrophilic nylon membrane GHP acrodiscs Gf and nylon acrodiscs Gf - Designed with a glass fiber prefilter over the membrane for hard to filter samples laden with particulate matter.
This syringe filter is made with GHP (hydrophilic polypropylene) membrane for low protein binding and features a polypropylene housing with female Luer-lock inlet and standard male slip Luer outlet connections. The membrane is HPLC certified for low levels of UV-absorbing extractables. Membrane: GHP Membrane. Pore Size: 0.45 µm. Typical hold-up volume: \\<100µL. Pall Life Sciences #: 4560.
The GHP membrane used in Pall Laboratory Acrodisc® syringe filters, centrifugal devices due to the rationalization of a key material from our supplier. Acrodisc PSF GxF Syr. Filters, GHP Membrane, 25 mm AP4559. Versatile filter for aqueous and aggressive organic solvent-based solutions. Low protein binding membrane gives high recovery of
removed prior to use by filtering a small amount of warm purified water through the membrane or filter unit. Surfactant-free cellulose acetate membranes with very low levels of extractables are available on some Corning® syringe filters. Cellulose nitrate (CN) membranes are recommended for filtering solutions where protein binding is not a
Syringe Filters. Pall supplies a comprehensive family of syringe filters offering a full range of sizes, volumes, and flow rates. Sterile syringe filters are typically used in life science applications to sterilize solutions or for clarification. Non-sterile syringe filters are used across a range of filtration and sample preparation applications. They are widely used in analytical chemistry for sample preparation, protecting analytical equipment from particle contamination.
Jan 7, 2023 · Please refer to our APO/FPO Shipping and Export Restrictions for more information on export to APO/FPO addresses. In addition to the Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences 66548/ 28143-288, we carry a full complement of Filters as well as other product offerings from Pall. We also carry a full line of Pall accessories
To recover analytes or other valuable components of interest after filtration, it is important to choose a filter with low nonspecific binding. For example, hydrophilic PVDF microporous membrane was found to be extremely inert and has both the lowest protein binding properties and the highest product recovery.
Pall GHP Polypropylene membrane will be discontinued effective October 31st, 2019. This discontinuation affects devices including syringe filters, filter plates, centrifugal devices and membrane filter discs. Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either