Pall Life Sciences® 4560 Acrodisc® Syringe Filters 25mm with

Pall Life Sciences® 4560 Acrodisc® Syringe Filters 25mm with GHP Membrane, 0.45 µm. Pore size of 0.45 µm with typical hold-up volume of \<100µl. Made with GHP (hydrophilic polypropylene) membrane for low protein binding. Features a polypropylene housing with female Luer-lock inlet and standard male slip Luer outlet connections.

Acrodisc® Units with Mustang® E Membrane - Endotoxin Removal

Inlet/Outlet Connections. Female luer lock inlet, male slip luer outlet; Membrane Bed Volume. 0.12 mL; Maximum Operating Temperature and Pressure. 2.1 bar (210 kPa, 30 psi) at 60 °C (140 °F) or 5.5 bar (550 kPa, 80 psi) at 21 - 24 °C (70 - 75 °F) Typical Differential Pressure < 0.07 bar (7 kPa, 1 psi) @ 1 mL/min; Mean Flow Rate

Acrodisc® PSF Syringe Filters

Female threaded luer inlet, male slip luer outlet AU T OM I N CERTIFIED ® AND Typical Hold-Up Maximum Maximum Typical Part Pore Volume Operating Operating Water Number Description Size (w/air purge) Temperature Pressure Flow Rate AP-4305 GxF/GHP 0.2 µm < 200 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 175 mL/min at 2.1 bar

Acrodisc® syringe filters membrane (GXF/GHP), diam. 25 mm

The 25 mm Acrodisc is recommended for sample volumes from 5 to 100 mL. The 13 mm size is recommended for samples under 10 mL in volume. The 4 mm size is for samples under 2 mL. PP housing with Luer fittings. GHP - hydrophilic PP membrane suitable for both aqueous and organic samples. GXF - multi-layered glass fiber prefilter.

Acrodisc® Syringe Filters for Prefiltration, Pall Laboratory

Polypropylene housing, female Luer-lock inlet and male slip Luer outlet. Certifications: Acrodisc PSF syringe filters are automation certified to assure smooth operation and worry-free performance 24 hours a day in automated workstations.

Acrodisc at Thomas Scientific

Pall® Acrodisc® Syringe Filter with PTFE Membrane. These syringe filters are ideal for filtration of gas and organic solvents Polypropylene housing HPLC certified The polypropylene housing is fitted with female Luer-lock inlet and male slip Luer outlet. The hydrophobic PTFE membrane, on a polypropylene support, has broad chemical.

Acrodisc Syringe Filters at Thomas Scientific

Manufacturer Pall Laboratory (17) female Luer-lock inlet and male slip Luer outlet. Certifications: Acrodisc PSF syringe ... standard male slip luer outlet Pore ...

Pall 4558 Acrodisc Syringe Filters with GHP Membrane, Pore

GHP (hydrophilic polypropylene) membrane is low protein binding. Both nylon and GHP membrane filters include a glass fiber prefilter layer, as well as being HPLC certified for low UV-absorbing extractables. The regular glass fiber membrane has very low extractables. Polypropylene housing. Female Luer-lock inlet and male slip Luer outlet.

Acrodisc® 13 mm Syringe Filter, 0.2 µm PTFE Minispike Outlet

Pall 13 mm Acrodisc syringe filters are available with a standard male slip luer outlet or Pall’s proprietary minispike outlet. The minispike allows for easy handling with a HPLC vial, and offers a reduced hold-up volume, ensuring maximum filtrate recovery. Typical hold-up volumes: 13 mm, male slip luer outlet: < 30 μm.

Pall Acrodisc Syringe Filters with Nylon Membrane - 0.45 m

Pall Acrodisc Syringe Filters with Nylon Membrane - 0.45 m, 13mm, male slip luer outlet (100/pkg 300/cs) Manufacturer: Pall 4426 Versatile Filter for Both Aqueous and Solvent-Based Sample Filtration.

4562 - GHP Membrane - Acrodisc Syringe Filters, 25mm, Pall

-Choice of media -Polypropylene housing -Luer-lock inlet Polypropylene housing with female Luer-lock inlet and standard male slip Luer outlet connections Typical hold-up volume: < - 100L. Note: PVDF membrane is not for use with acetone, DMF, DMSO, or bases > - 6N. All membranes are HPLC certified for low levels of UV-absorbing extractables.

Acrodisc® Syringe Filters with PTFE Membrane

4555 0.45 µm, minispike outlet 1000/pkg NA 0 Acrodisc Syringe Filters with PTFE Membrane, 13 mm 4423 0.2 µm, male slip luer outlet 100/pkg 300/cs NA 0 4542 0.2 µm, male slip luer outlet 1000/pkg NA 0 4422 0.45 µm, male slip luer outlet 100/pkg 300/cs NA 0 4543 0.45 µm, male slip luer outlet 1000/pkg NA 0

12-4610 12-4610-01 4554 GHP Acrodisc 12-4610-03 4556 12-4610

Ideal for filtering samples and HPLC mobile phases. Polypropylene housing. The 13mm fiklter has a female Luer lock inlet and a minispike outlet while the 25mm filter has a female Luer lock inlet and a male slip Luer outlet. The GHP Acrodisc® GF syringe filter version includes a glass fiber prefilter layer for hard-to-filter samples.

4566 - GHP Membrane - Acrodisc Syringe Filters, 25mm, Pall

-Choice of media -Polypropylene housing -Luer-lock inlet Polypropylene housing with female Luer-lock inlet and standard male slip Luer outlet connections Typical hold-up volume: < - 100L. Note: PVDF membrane is not for use with acetone, DMF, DMSO, or bases > - 6N. All membranes are HPLC certified for low levels of UV-absorbing extractables.

PALL ACRODISC SYRINGE FILTERS - vgdusa.com

Female Luer-Lok inlet and standard male slip Luer outlet. Sterile. Modified acrylic housing. 50/pk. 1.8. $168.32. 4651. Acrodisc Syringe Filter with Supor Membrane Red. 0.1um pore size. 32mm diameter. For biological research. Polyethersulfone membrane provides high throughput and fast flow rate. Female Luer-Lok inlet and standard male slip Luer