Home » News » GHP Filter » GH Polypro membrane sterile on stock

GH Polypro membrane sterile on stock

Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 um Pall® 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000 . Filter Media: Glass Fiber / G...
Product Introduction

Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 um

Pall® 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000 . Filter Media: Glass Fiber / GH Polypro membrane (GHP, hydrophilic polypropylene)

PTFE Membrane Filters | Products & Suppliers | Engineering360

To determine the tolerance of each membrane to chemicals, white polycarbonate, MF-Millipore, cellulose acetate, hydrophilic polypropylene and hydrophilic PTFE membrane filters that had low auto-fluorescence were mounted in chambers (37 mm monitor unit; Advantec Co. Ltd., Tokyo, Japan).

USABlueBook - GH Polypro (GHP) Membrane Disc Filters‚ 0

GH Polypro (GHP) Membrane Disc Filters‚ 0.45um pore size x 47mm diameter‚ 100/pk, 28143-288 Please note, due to volume, carriers have advised of potential delays. We appreciate your patience during this unprecedented time.

Whatman PTFE membrane filters PTFE membrane - Whatman filter

Sterile venting of vacuum manifolds, fermentation vessels, and sterile filtrate tanks and containers utilize PTFE 0.2 μm membranes. WTP and TE membrane ranges: WTP membranes use a polypropylene grid as the support material whereas the TE range use a randomly arranged polypropylene support material.

EMD Millipore MPGL06GH2 60 Filter, 30L, 0.22um PVDF, 1/4" ID

Specifications & Description. Membrane Material Polypropylene. Pore Size (µm) 0.22. Housing Material Polypropylene (PP) Sample Volume (mL) 300. Sterile Yes. Description 60 Filter, 30L, 0.22um PVDF, 1/4" ID, Sterile; 2/Pk. Key Features. Maximum inlet pressure is 75 psi at 25 °C.

Filtration Products by 3M

and sterile formats. • Formerly known as SterASSURE. • Multi-zone microporous membrane design. • Advanced Pleat Technology (APT). • Available in 0.1 and 0.2 μm absolute rating in Cartridge, Mini Cartridge and Capsule format. • Nylon 6,6 membrane in an all-polypropylene construction. • Validated and DMF. • Formerly known as

Poly-Fine® II Series Filter Cartridges - Pre Storage and

Description. The Poly-Fine II element is a high area, pleated all-polypropylene depth filter frequently used in a wide variety of applications for particle removal. It is a cost-effective choice for final particle removal, or for pre-filtration, including reliable protection of final membrane filters.

US20070119771A1 - Cross-flow membrane module - Google Patents

The second layer pair includes a second polymeric microporous membrane and a second flow channel layer oriented in a second flow direction different than the first flow direction and having a fluid inlet and a fluid outlet disposed on second opposing sides of the extraction element.

A high-throughput differential filtration assay to screen and

Dec 01, 2010 · The MW distributions of these two MWCO filtered microplates along with the 0.2 μm GHP (GH hydrophobic polypropylene) filter plate are shown in Fig. 2. As expected, the 0.2 μm plate allows passage of all the gel filtration standards, with equal and complete permeability of all standards except blue dextran (partially permeable).

SUEZ (GE) Flat Sheet Membrane, GH, PA-TFC, UF, 305 x 305mm, 1/Pk

Used flat sheet membranes must always remain wet, including during storage. Membranes that are allowed to dry will irreversibly loose water permeability. To prevent microbial growth, the membranes can be stored in a 0.5% solution of formaldehyde. Alternatively, the membranes can be stored in a 1.0% solution of sodium metabisulfite (SMBS).

Activator Solution- 0.45 M ±0.02 of Tetrazole along with

Stocking a variety of filters is both expensive and inconvenient. Now you can stock just one syringe filter in the lab that is compatible with a wide range of solvents. Pall Gelman’s universal solvent filter is the GHP Acrodisc, which includes an all-purpose membrane, GH Polypro

Membrane Filters for Lab Filtration - analytics-shop.com

Some membrane materials are also available sterile. Membrane filters are typically used in both liquid and air filtration. They offer accurately controlled pore size distribution with high strength and flexibility, and are suitable for a wide range of applications such as basic research, environmental testing and pharmaceutical as well as food

Syringe filters - Sigma-Aldrich

Millex-HV Syringe Filter Unit, 0.45 µm. A 13 mm diameter sterile syringe filter with a 0.45 µm pore size hydrophilic PVDF membrane. Comes in a pack of 100. A 4 mm diameter sterile syringe filter with a 0.45 µm pore size hydrophilic PVDF membrane. Comes in a pack of 100.

Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life

Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences is a reliable and dependable addition to the Pall Filters family of products. Combining top-notch and uncompromising quality with an affordable price, the Pall GH Polypro (GHP) Membrane Disc Filters, Pall Life Sciences 66548/ 28143-288 can fulfill your laboratory needs while still offering a great value for the money.

Membrane fouling in sterile filtration of recombinant human

May 05, 1996 · This article presents our study on sterile filtration of a model protein, recombinant human growth hormone (rhGH). Scanning electron microscopy (SEM) analysis shows that 0.22-μm membranes, when used to filter the mannitol-formulated protein solution under a 0.35-bar transmembrane pressure, were plugged to a great extent.