Home » News » GHP Filter » Free sample GH Polypro membrane maximum operating pressure 2.1 bar

Free sample GH Polypro membrane maximum operating pressure 2.1 bar

Acrodisc PSF Syringe Filters – Medigene Sdn. Bhd. • Available with GHP hydrophilic polypropylene membrane for maximum chemical compatibility, AP-4219 2.1 bar at 21-24 °C (70-75 °F) (100 kPa,...
Product Introduction

Acrodisc PSF Syringe Filters - Medigene Sdn. Bhd.

• Available with GHP hydrophilic polypropylene membrane for maximum chemical compatibility, AP-4219 2.1 bar at 21-24 °C (70-75 °F) (100 kPa, 15 psi ...

integra hp - SUEZ Water Technologies

Maximum TDS (ppm) 1000 Minimum inlet pressure - psi (bar) 30 (2.1) Maximum inlet pressure - psi (bar) 90 (6.2) Feedwater temperature 1-35oC Flowrate 400l/hr (min) Free chlorine Must be dechlorinated System Specification Pure water storage 50 litre Display panel LCD – Colour touch screen Pre-treatment 5μm pre-filter Reverse osmosis Low energy

Sartopore® 2 Cartridge 0.2µm | Sartorius

Sartopore ® 2 XLI Pore size: 0.35 | 0.2 µm (heterogeneous PES double layer) It is the identical final 0.2 µm membrane layer which ensures sterility of your product. But it is the pre-filter porosity which makes the difference. Depending on specific product properties a finer or coarser pre-filter layer can significantly improve the capacity

25 mm, Acrodisc® Syringe Filter, 0.45 µm, GF/Nylon Membrane

Maximum Operating Pressure (bar) 2.1 bar 55°C. Typical Flow Rate. 215 mL/min at 2.1 bar (210 kPa, 30 psi) ... Filtering a sample prior to sample injection into ...

Product Guide and Page Index - Aijiren Tech Sci

plastic of the sample container: Adsorption to the membrane. Depending on sample characteristics relative to the membrane type used, solute adsorption on the membrane surface is typically 2-10 µg/cm2. This can increase to 20-100µg/cm2 when the filtrate is of interest and the solute must pass through the whole internal structure of the membrane.

BioSMB Process 80/350 - Sartorius

Pressure. 7 pressure transmitters (1 after each pump with integrated pressure switch) 0 to 5 barg/72 psig (NOTE: Maximum operating pressure for system is 4 barg/58 psig) Flow. 7 ultrasonic non-invasive flowmeters (1 after each pump) Air. 7 integrated with flowmeters. Conductivity

AcroPak™ 500, 1000, & 1500 Capsules with Supor® Membrane

Housing, Vent Plug, and Filter Support: Polypropylene (140 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure ... with Supor® Membranes Stainless Steel ...

Ceramic vs polymeric membrane implementation for potable

Mar 08, 2022 · In the most recent study ( Kurth et al, 2018) a net flux of up to 381 LMH was assumed (based on the outcomes of a pilot trial) along with an implied cost of ∼$175 USD per m 2 for the ceramic membrane, compared with $35 USD m −2 for the polymeric one operating at a net flux of 68 LMH.

Performance of a polypropylene membrane contactor for the

Oct 01, 2018 · A polypropylene membrane contactor was used for the recovery of dissolved methane from an anaerobic reactor effluent. Effect of operational parameters, operation mode and fouling on long-term operation was studied using vacuum pressure or N 2 as sweep gas. Results were analyzed based on the mass transfer estimations.

Composite amine mixed matrix membranes for high-pressure CO2

Sep 09, 2020 · The presented values have been calculated by equations (2.1) and (2.2). The figures exhibit a reduction in permeance and an increase in selectivity with the increase in pressure. In figure 8a, the maximum permeance is at a lower pressure of 10 bar, and as pressures approach 30 bar, the permeability is moved towards minimum value. The percentage

Acrodisc® 25 mm Syringe Filter, 0.2 µm PTFE Membrane, 1000

Maximum Operating Pressure (bar) 2.1 bar. Maximum Operating Temperature (Metric) 100 °C. Typical Flow Rate.

Chemical Engineering Thermodynamics II - CPP

2.1 Type of Thermodynamic Properties 2-1 Example 2.1-1: Electrolysis of water 2-3 Example 2.1-2: Voltage of a hydrogen fuel cell 2-4 2.2 Fundamental Property Relations 2-5 Example 2.2-1: Finding the saturation pressure 2-8 2.3 Equations of State 2-11 2.3-1 The Virial Equation of State 2-11 Example 2.3-1: Estimate the tank pressure 2-12

Popular GH Polypro membrane maximum operating pressure 2.1

Popular GH Polypro membrane maximum operating pressure 2.1 bar Natural Organic Matter Removal and Fouling in a Low Pressure Jan 08, 2014 · The NOM rejection and membrane fouling were performed on commercial polypropylene hollow fiber MF (Zena Membranes, Czec

low protein binding membrane ghp syringe filter maximum

Supor® EKV Membrane Filters - Membrane Filters - PallMaximum Operating Temperature * 60 ºC (140 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure* 5.4 bar (540 kPa, 80 p

Lenntech

Housing: Polypropylene Polypropylene Glass-filled polypropylene Standard Connections Female Luer-Lok, male luer slip fittings 3/4 in. Sanitary flange Disposable 11/2 in. TC fitting Vent/Drain — 1/8 in. Hose barb Disposable vent Maximum Operating 4.1 bar (60 psi) 5.5 bar (80 psi) 3.4 bar (50 psi) Line Pressure (at 23 °C)

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.