Home » News » GHP Filter » female luer lok inlet ghp membrane lower hold-up volume

female luer lok inlet ghp membrane lower hold-up volume

Acrodisc wwPTFE Syringe Filters | Pall- MG – MG Scientific Sample Volume: 13mm is
Product Introduction

Acrodisc wwPTFE Syringe Filters | Pall- MG - MG Scientific

Sample Volume: 13mm is <10mL 25mm is < 100mL 25mm Premium is < 150mL: Inlet/Outlet Connections: 13mm is Female Luer-Lok inlet with minispike outlet. 25mm is Female Luer-Lok inlet with male slip luer outlet: Typical Hold-up Volume (with air purge) 13mm is <14µL 25mm is <100µL 25mm GF is <125µL: Maximum Operating Temperature: 55°C (131°F

Syringe Luer-Lok at Thomas Scientific

Inorganic Membrane with a membrane diameter of 10 mm; mean pore size of 0.2 mm; operating pressure of 100 psi maximum; membrane thickness of 60 mm; hold-up volume of 20 mL; inlet connection is female Luer-Lok; outlet connection is male Luer-Slip; housing material of neutral color polypropylene.

Millex-FG, 0.20 µm, hydrophobic PTFE, 25 mm | Letco Medical

Connections, Inlet/Outlet: Female Luer-Lok/Male Luer-Lok; Fitting Inlet: Female Luer-Lok® Fitting Outlet: Male Luer-Lok® Color Code: Blue inlet/blue outlet; Maximum Inlet Pressure, bar (psi): 5.2 bar (75 psi) Maximum Operating Temperature: 45 °C; Direct Patient Care (Y/N): Y; Sterilization: Ethylene oxide; Hold-up Volume: <0.1mL; Device

PALL FILTERS - vgdusa.com

Female Luer-Lok inlet and minispike outlet.\<14uL hold-up volume. 100/pk 300/cs. Pall Filter 4457. Acrodisc Syringe Filter13mm 0.45um. Hydrophilic polyvinylidine fluoride membrane. HPLC certified for low levels of UV-absorbing extractables. Polypropylene housing. Female Luer-Lok inlet male slip Luer outlet.\<30uL hold-up volume. 100psi pressure.

Instructions For Use Pall Minidisc Filter Capsules with

2. Connect the inlet of the capsule to the 3-way Luer-Lok valve. 3. Connect the valve to the pressure vessel via the male Luer-Lok. 4. Ensure that the unconnected female Luer port is shut off by the valve. 5. Insert and hold the capsule so that the outlet of the filter points upward (Figure 2: Recommended Wetting Procedure). 6.

Hydrophilic Polypropylene at Thomas Scientific

EZFlow® High Particulate Syringe Filters. membrane along with a glass fiber pre-filter. The filter membrane is available in PES or Hydrophilic PVDF materials, offered in 0.2µm or 0.45µm pore sizes. The filter membrane is reinforced with a polypropylene housing with a female Luer-Lok inlet and a male Luer Slip outlet.

Luer lok at Thomas Scientific

Luer lok found in: Cap Female Luer Lok S / Su, Plastipak Disposable Syringes with Needles, 1mL Luer-Lok™ Syringe/Needle Combination, Sterile, Disposable,..

Certified luer lock PTFE membrane filter on stock-Analytical

Dec 21, 2021 · Inlet/Outlet Connections: Female Luer Lock/Male Luer. Membrane: PTFE. Retention: 5.0µm. 100/Pack. Whatman™ #: 6784-1350. Documents & Videos. This Puradisc™ 13 syringe filter combines premium quality and economy. These 13mm syringe filters are ideal for the quick efficient filtration of samples up to 10mL volume. They are produced from

Pall Acrodisc Filters - vgdusa.com

Acrodisc Syringe Filter 25mm 0.45um. Hydrophobic PTFE membrane for exceptional chemical and temperature compatibility. HPLC certified for low level UV-absorbing extractables. Polypropylene housing. Female Luer-Lok inlet standard male slip Luer outlet. \<100uL hold-up volume. 50/pk. 200/cs. 1.4. $718.92. 4219.

syringe filter 1-2 - ENFISO

Female Luer-Lok inlet / Male Luer slip outlet Ordering Information Pore Size(˛m) Hold -up Volume Qty/pk Catalogue No. 13mm Cosmo ® for 1-10mL volume 25mm Cosmo ® for 10-100mL volume ® Hydrophilic PVDF PES 0.22 0.45 SFU13PVH0022 SFU13PVH0045 SFU13PE0022 SFU13PE0045 < 25˛L < 25˛L 100 100 0.22 0.45 < 25˛L < 25˛L 100 100 0.22 0.45 < 25˛L

PALL ACRODISC SYRINGE FILTERS - ww-w.vgdusa.com

4219. Acrodisc Syringe Filter 25mm 0.45um. Hydrophobic PTFE membrane for exceptional chemical and temperature compatibility. HPLC certified for low level UV-absorbing extractables. Polypropylene housing. Female Luer-Lok inlet standard male slip Luer outlet. \<100uL hold-up volume. 50/pk. 200/cs.

Millipore SLGN013NK Nylon Millex-GN Non-Sterile Syringe

Inlet to outlet (with Male Luer Slip Outlet): 21mm (0.83"), 15mm diameter, 45 degrees celsius maximum temperature limit, 100 psig Pressure limit at 25 degrees celsius, =10mL Filtration volume, =25 L Hold-up volume after air purge at pressure that exceeds bubble point of the membrane. Female luer-lok inlet and male luer slip outlet connection.

Acrodisc® Syringe Filters with GHP Membrane - HPLC/UHPLC

Sample Volume. 13 mm: < 10 mL; 25 mm PSF: < 150 mL; Inlet/Outlet Connections. 13 mm: Female luer lok inlet, minispike outlet; 25 mm PSF: Female luer lok inlet, male slip luer outlet; Typical Hold-up Volume(with air purge) 13 mm: < 14 µL; 25 mm PSF: < 125 µL; 25 mm PSF GxF: < 200 µL; Maximum Operating Temperature

Pall Minidisc Filter Capsules with Ultipor DV20 Virus Removal

2. Connect the inlet of the capsule to the 3-way Luer-Lok valve. 3. Connect the valve to the pressure vessel via the male Luer-Lok. 4. Ensure that the unconnected female Luer port is shut off by the valve. 5. Insert and hold the capsule so that the outlet of the filter points upward (Figure 2: Recommended Wetting Procedure). 6.

Aijiren Tech Scientific SLHVR33RS - McKesson Medical-Surgical

Syringe Filter 33 mm dia., 200 mL, Yellow, 0.1 µm Pore Size, 145 psi Pressure Rating, Female Luer Lok Inlet Style, Male Luer Slip Outlet Style, 100 µL Hold up Volume, 45°C Temperature, Modified Acrylic Tip, Sterile 100% integrity tested, individually packaged and sterilized Female Luer-Lok™ inlet and male Luer slip outlet

Related Products
Send Your Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Country :
Email:
Phone:
Inquiry:
Quick Consultation
Name:
Email:
Phone:
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.