Home » News » GHP Filter » female luer lok inlet ghp filters sample volume less 10ul

female luer lok inlet ghp filters sample volume less 10ul

Millex Syringe Filter, PES, Non-sterile 0.45 µm pore size, 13 • Non-sterile Millex syringe filters with Millipore Express PLUS polyethersulfone (PES) membrane provide fast filtration of aqueous an...
Product Introduction

Millex Syringe Filter, PES, Non-sterile 0.45 µm pore size, 13

• Non-sterile Millex syringe filters with Millipore Express PLUS polyethersulfone (PES) membrane provide fast filtration of aqueous and mild organic solutions. • Available in 0.22 µm and 0.45 µm pore sizes and two diameters to suit your application needs • Low protein binding to minimize interaction with your sample and maximize recovery

us.cmd.vwr.com

Jun 09, 2022 · PartNum ShortDesc UoM ContractPrice CurrencyCode UNSPSCv131201 ActionCode PartNumExt LongDesc KeyWords MfrName MfrPartNum NYSPartNum MinOrder MaxOrder OrderInterval

luer lock ghp acrodisc sample volume less 10ul-Lab

high performance pall ghp sample volume less 10ul-Lab . Sample Prep Filtration Products for UHPLC - Pall. Sample Prep Filtration Products for UHPLC Ultra High Performance Liquid Chromatography (UHPLC) sample prep filtration significantly increases column life and improves chromatography Applications These 0.2 µm syringe filters and mem - branes have been developed for UHPLC sample prep and

Acrodisc® syringe filters GHP membrane, diam - Sigma-Aldrich

The 25 mm Acrodisc is recommended for sample volumes from 5 to 100 mL. The 13 mm size is recommended for samples under 10 mL in volume. The 4 mm size is for samples under 2 mL. PP housing with Luer fittings. GHP - hydrophilic PP membrane suitable for both aqueous and organic samples; GXF - multi-layered glass fiber prefilter

Syringe Filters with Luer Lock Inlet, Restek - VWR

Syrings filters have guaranteed leak-tight connections with luer lock inlets.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove

Hydrophilic Filter, Female Luer Lock Inlet, Male - Qosina

Qosina offers an extensive line of hydrophilic and hydrophobic filters in a variety of configurations that are in stock and ready for immediate delivery. Ideal for fluids, Qosina part #28304 is a hydrophilic filter with a female luer lock inlet and male luer lock outlet. Made with an acrylic housing and supor filter media, this green filter is ergonomic and offers low back pressure.

luer lock ghp syringe filter sample volume less 10ul

Syringe Filter at Thomas ScientificFinneran 13mm Mini-Tip Syringe Filters provide extremely low dead volume of less than 10ul, and are available in 0.2um and 0.45um pore sizes. Au Tel: 8618057059123

male slip luer outlet ghp acrodisc sample volume less 10ul

Male slip Luer outlet.\. 10uL hold-up volume. 75psi pressure. Nonsterile autoclavable. Pall Filter 4472. Acrodisc Syringe Filter 4mm 0.45um. 4mm diameter.

high performance pall ghp sample volume less 10ul-Lab

Pipet-Lite™ XLS+ manual 12-channel pipette, 0.5-10 μL, uses LTS™ LiteTouch™ tips. Consistent sample pickup. Accurate,precise, ergonomic, volume lock, rugged, durable (L12-10XLS+) Fatigue-free pipetting and total control. Effortless pipetting due to light weight, light plunger forces and lowest tip ejection.

Syringe Filters with Luer Lock Inlet - Restek

Luer lock inlet offers leak-tight syringe connection. Variety of filter types, porosities, and diameters. Color coded for easy identification. Rugged polypropylene housing. Autoclavable to 121 °C for 15 minutes. Quantity break pricing for greater savings. Note: Syringe filters are for laboratory use only.

female luer lok inlet ghp membrane filter lower hold-up volume

GHP membrane also has an extremely low autofluorescence level, so the membrane Hold-Up Volume (Membrane/Support): Inlet: Threaded female luer lock. HPLC and Chromatography Sample Prep - VWR. Acrodisc PSF syringe filters with GHP membrane A filter with a low hold-up volume is recommended for ... 25 mm PSF: Female luer lock inlet,.

Hydrophobic Filter with Female Luer Lock Inlet, Male - Qosina

Qosina is a leading supplier of Hydrophobic Filter with Female Luer Lock Inlet, Male Luer Lock Outlet with 17 mm, 0.45 Micron. Get fast shipping and volume discounts on Gas parts.

hydrophobic ghp syringe filter sample volume less 10ul

Acrodisc® Syringe Filters - Pall Corporation. For HPLC Sample Preparation and Solvent or Aqueous Filtration GHP Acrodisc Minispike, 0.45 µm, 13 mm. 100/300 CAUTION: Use of syringes smaller. PALL FILTERS - vgdusa. 0.8cm2 filtration area. \ 10ml sample volume.

female luer lok inlet ghp membrane lower hold-up volume

Acrodisc wwPTFE Syringe Filters | Pall- MG - MG Scientific. Sample Volume: 13mm is . 10mL 25mm is 100mL 25mm Premium is 150mL: Inlet/Outlet Connections: 13mm is Female Luer-Lok inlet with minispike outlet. 25mm is Female Luer-Lok inlet with male slip luer outlet: Typical Hold-up Volume (with air purge) 13mm is 14µL 25mm is 100µL 25mm GF is 125µL: Maximum Operating Temperature: 55°C (131°F

Hydrophobic Filter with Female Luer Lock Inlet, Male - Qosina

Qosina is a leading supplier of Hydrophobic Filter with Female Luer Lock Inlet, Male Luer Lock Outlet with 17 mm, 0.45 Micron. Get fast shipping and volume discounts on Gas parts.