Syringe Filter 33 mm dia., <200 mL, Yellow, 0.1 µm Pore Size, 145 psi Pressure Rating, Female Luer Lok Inlet Style, Male Luer Slip Outlet Style, <100 µL Hold up Volume, 45°C Temperature, Modified Acrylic Tip, Sterile. 100% integrity tested, individually packaged and sterilized. Female Luer-Lok™ inlet and male Luer slip outlet.
2 bar,2 Micron, Inlet and Outlet Female Luer-Lok x Male Luer Slip Connection, 25mm Diameter (Pack of 50): Science Lab Inline Filters: Industrial & Scientific,Millipore SLFG025LS In Line Filter Hydrophobic PTFE Hydrophobic PTFE Millex-FG In Line Filter Unit, 5, Here are your favorite items High-End Contemporary Fashion 20% Off Clearance, Shop Now E-shopping is the most convenient choice
Connections: Female Luer-Lok* inlet, male slip luer outlet Membrane Bed Volume ~ 0.18 mL Differential Pressure < 1 psi at 1 mL/min Typical Operating Temperature 21 - 24 °C (70 - 75 °F) Maximum Operating Pressure 5.5 bar (80 psi) Mean Dynamic Binding Capacity† DNA ~ 3.6 mg/Acrodisc unit or ~ 20 mg/mL membrane volume BSA ~ 10 mg/Acrodisc unit
Shop Acrodisc GHP | 25 mm 0.2 µm | WAT097964 | Aijiren TechnologyAijiren Technology inventory is limited. Part number 186009327 is the recommended replacement. Aijiren Technology offers scientists and lab managers A
Sample Volume. 13 mm: < 10 mL; 25 mm PSF: < 150 mL; Inlet/Outlet Connections. 13 mm: Female luer lok inlet, minispike outlet; 25 mm PSF: Female luer lok inlet, male slip luer outlet; Typical Hold-up Volume(with air purge) 13 mm: < 14 µL; 25 mm PSF: < 125 µL; 25 mm PSF GxF: < 200 µL; Maximum Operating Temperature
Close; Molded Parts & Components. Molded Parts & Components. Adapters & Rotators; Caps & Covers; Hubs; Luers & Connectors; Cultura™ Transport Vial; Neuraxial Components: ISO 80369-6
leukocyte recovery applications. The sterile Acrodisc WBC syringe filter yields greater cell capture and recovery with less sample compared to larger filter formats and also exudes very low hold up volume as compared to larger white blood cell isolation filters (hold up volume < 2 mL, with total
Inlet/Outlet Connections Inlet: Female luer lok Outlet: Male luer outlet or minispike as noted Typical Hold-up Volume (with air purge) 13 mm minispike: < 14 μL 13 mm: < 30 μL 25 mm: < 100 μL Maximum Operating Temperature wwPTFE, Nylon, PES: 55 °C (131 °F) PTFE, PVDF: 100 °C (212 °F) Glass Fiber: 135 °C (275 °F) Maximum Operating Pressure
Pall® Acrodisc® Syringe Filter with PTFE Membrane. These syringe filters are ideal for filtration of gas and organic solvents Polypropylene housing HPLC certified The polypropylene housing is fitted with female Luer-lock inlet and male slip Luer outlet. The hydrophobic PTFE membrane, on a polypropylene support, has broad chemical.
Pall Ghp Acrodisc 13MS 2UM 100PK Ghp Acrodisc 13MS 2UM 100PK is a reliable and dependable addition to the Pall Filters family of products. Combining top-notch and uncompromising quality with an affordable price, the Pall Ghp Acrodisc 13MS 2UM 100PK Ghp Acrodisc 13MS 2UM 100PK 4554/ 28139-550 can fulfill your laboratory needs while still offering a great value for the money.
Oct 29, 2021 · A 25 mm diameter sterile syringe filter with a 0.2 µm pore size hydrophilic PTFE membrane. Female Luer-Lok™ inlet and male Luer slip outlet Ethylene oxide sterilized Comes in a pack of 50 Female Luer-Lok™ inlet and male Luer slip outlet Ethylene oxide sterilized Comes in a pack of 50
Female Luer-Lok inlet and minispike outlet.\<14uL hold-up volume. 100/pk 300/cs. Pall Filter 4457. Acrodisc Syringe Filter13mm 0.45um. Hydrophilic polyvinylidine fluoride membrane. HPLC certified for low levels of UV-absorbing extractables. Polypropylene housing. Female Luer-Lok inlet male slip Luer outlet.\<30uL hold-up volume. 100psi pressure.
Pall 4558 Acrodisc Syringe Filters with GHP Membrane, Pore Size 0.45 µm, Diameter 25 mm, Pack of 1000: Industrial & Scientific. Automation Certified to ensure smooth operation and worry-free performance 24 hours a day in automated workstations.
CONSTANTS AND VARIABLE DESCRIPTIONS Vs = total initial sample volume V = cumulative volume of titrant added C = total carbonate expressed in moles L"1 [H+] = hydrogen ion concentration Kj_ = 7.079 x 10~7 at 25 °C and 0.1M ionic strength (Butler, 1982) K2 = 1.202 x 10"10 at 25 °C and 0.1M ionic strength K,, = 1.660 x 10"14 at 25 °C and 0.1M
Sample Volume. 13 mm: < 10 mL; 25 mm PSF: < 150 mL; Inlet/Outlet Connections. 13 mm: Female luer lok inlet, minispike outlet; 25 mm PSF: Female luer lok inlet, male slip luer outlet; Typical Hold-up Volume(with air purge) 13 mm: < 14 µL; 25 mm PSF: < 125 µL; 25 mm PSF GxF: < 200 µL; Maximum Operating Temperature