Nalgene Syringe Filters have a female Luer-lock inlet and a male Luer slip outlet Pall Acrodisc Syringe Filter Tuffryn Membranes have low hold-up volume Sterile Acrodisc® Syringe Filters expensive samples, hold-up volume (sample loss) can be a concern and a smaller Female luer lock inlet, male slip luer outlet. Typical Hold-up Volume.
Syringe Filter 33 mm dia., 200 mL, Yellow, 0.1 µm Pore Size, 145 psi Pressure Rating, Female Luer Lok Inlet Style, Male Luer Slip Outlet Style, 100 µL Hold up Volume, 45°C Temperature, Modified Acrylic Tip, Sterile 100% integrity tested, individually packaged and sterilized Female Luer-Lok™ inlet and male Luer slip outlet
Syringe Filter 33 mm dia., 200 mL, Yellow, 0.1 µm Pore Size, 145 psi Pressure Rating, Female Luer Lok Inlet Style, Male Luer Slip Outlet Style, 100 µL Hold up Volume, 45°C Temperature, Modified Acrylic Tip, Sterile 100% integrity tested, individually packaged and sterilized Female Luer-Lok™ inlet and male Luer slip outlet
Acrodisc® Syringe Filters Polypropylene housing with female Luer-Lock inlet and standard male slip Luer outlet connections. All membranes are HPLC certified for low levels of UV-absorbing extractables. Typical hold-up volume: <100µL. 1229P20 AutoPack packaging features 25 filters pre-packaged in each dispenser tube. Eight tubes per case.
Acrodisc® Syringe Filters, 25 mm, Pall Laboratory. Filters Syringe Filters. These 25 mm syringe filters offer an available prefiltration layer and wide choice of filter media. Wide range of filter media available. Available in 0.2 µm for UHPLC applications. Available with pre-filter for difficult to filter samples.
Female Luer-Lok. inlet/male luer outlet or minispike outlet as noted. Typical Hold-up Volume (with air purge) 4 mm: < 10 µL. 13 mm minispike: < 14 µL
Inlet/Outlet Connections Female luer-lok inlet, male slip luer outlet Typical Hold-up Volume (with air purge) < 50 µL Maximum Operating Temperature 55 °C (131 °F) Maximum Operating Pressure 6.2 bar (620 kPa, 90 psi) Typical Water Flow Rate 60 mL/min at 2.1 bar (210 kPa, 30 psi) Endotoxin Level
Female Luer-Lok♦ inlet and outlet Membrane Bed Volume 0.86 mL Differential Pressure < 15 psi at 10 mL/min Maximum Operating Temperature and Pressure 37 °C (99 °F) 4 bar (400 kPa, 60 psi) Mean Dynamic Binding Capacity* BSA ~ 70 mg/mL membrane volume for Mustang Q XT Acrodisc Unit Lysozyme ~ 30 mg/mL membrane volume for Mustang S XT Acrodisc Unit
Acrodisc Syringe Filter 4mm 0.45um. 4mm diameter. Hydrophobic PTFE membrane. Polypropylene support. Chemically compatible. HPLC certified for low level UV-absorbing extractables. Female Luer-Lok inlet. Male slip Luer outlet.\<10uL hold-up volume. 75psi pressure. Nonsterile autoclavable.
Sample Volume 13 mm: < 10 mL 25 mm: < 100 mL Inlet/Outlet Connections Inlet: Female luer lok Outlet: Male luer outlet or minispike as noted Typical Hold-up Volume (with air purge) 13 mm minispike: < 14 μL 13 mm: < 30 μL 25 mm: < 100 μL Maximum Operating Temperature wwPTFE, Nylon, PES: 55 °C (131 °F) PTFE, PVDF: 100 °C (212 °F)
Home » News » GHP Filter » Common use ghp filters lower hold-up volume Common use ghp filters lower hold-up volume Doppler ultrasonography of the lower extremity arteries Jan 18, 2017 · Doppler US of the lower extremity begins at the inguinal crease by putting a transducer on the common femoral artery in the
Pall Life Sciences® 4560 Acrodisc® Syringe Filters 25mm with GHP Membrane, 0.45 µm. Pore size of 0.45 µm with typical hold-up volume of \ 100µl. Made with GHP (hydrophilic polypropylene) membrane for low protein binding. Features a polypropylene housing with female Luer-lock inlet and standard male slip Luer outlet connections.
Minispike Acrodisc 13mm Syringe Filter 0.2um pore. Hydrophilic PVDF membrane for aqueous nonaggressive solvent-based mobile phases. HPLC certified for low UV-absorbing extractables. Polypropylene housing. Female Luer-Lok inlet minispike outlet.\<14uL hold-up volume. 100/pk 300/cs.
Inlet/Outlet Connections. 13 mm: Female luer lok inlet, minispike outlet; 25 mm PSF: Female luer lok inlet, male slip luer outlet; Typical Hold-up Volume(with air purge) 13 mm: < 14 µL; 25 mm PSF: < 125 µL; 25 mm PSF GxF: < 200 µL; Maximum Operating Temperature. 25 mm PSF: 55 ºC (131 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure
Syringe Filter 33 mm dia., 100 mL, Blue, 0.45 µm Pore Size, 145 psi Pressure Rating, Female Luer Lok Inlet Style, Male Luer Slip Outlet Style, <100 µL Hold up Volume, 45°C Temperature, Modified Acrylic Tip, Sterile Aijiren Tech Scientific SLHAM33SS