Supor EKV Membrane Filters – VWR 97035-164 4902 Acrodisc Syringe Filter with Supor EKV 50/pkg membrane, 0.2 µm, 25 mm 97035-166 12246 AcroPak 20 Filter with Supor EKV 3/pkg membrane, 0.2 µm, ...
Product Introduction

Supor EKV Membrane Filters - VWR

97035-164 4902 Acrodisc Syringe Filter with Supor EKV 50/pkg membrane, 0.2 µm, 25 mm 97035-166 12246 AcroPak 20 Filter with Supor EKV 3/pkg membrane, 0.2 µm, non-sterile 97035-168 12247 AcroPak 20 Filter with Supor EKV 3/pkg membrane, 0.2 µm, sterilized 97035-170 12094 AcroPak 200 Capsule with Supor EKV 3/pkg membrane, 0.2 µm, tapered hose barb

Depth Filtration BECODISC BS Range Stacked Disc Cartridges

maximum operating pressure. High-proof alcohol solutions and products that do not allow pre-rinsing with water should be circulated for 10 to 20 minutes. Dispose of the rinsing solution after rinsing. Terminate the filtration process once the maximum permitted differential pressure of 43.5 psi (300 kPa, 3 bar) is reached.

PureFlo® PTFE Features / Benefits

Recommended Operating Conditions (for untreated/non-sterile product) Disc (D) Junior (JKP) Mini (MKP) Mid (SKV) Full (L) Maximum Temperature 80 °C 80 °C 80 °C 80 °C 80 °C Maximum Inlet Pressure (at 22 °C) 5.5 bar | 80 psi 5.5 bar | 80 psi 5.5 bar | 80 psi 5.5 bar | 80 psi 5.5 bar | 80 psi Maximum Forward Differential Pressure (at 22 °C)

Pegasus™ SV4 Virus Removal Filter Cartridges

Core, Cage and Endcaps Polypropylene Code 7 Adapter Polypropylene with encapsulated stainless steel reinforcing ring O-rings Silicone Recommended Operating Differential Pressure 2.1 to 3.1 bard (30 to 45 psid) Maximum Differential Pressure 3.1 bard (45 psid) for continuous service 0.3 bard (4.3 psid) during steam sterilization

Microdisc Capsules with Pegasus™ Prime Virus Removal Filter

Operating Parameters Maximum temperature: 40 °C Maximum pressure: 3.1 bar (45 psi)* Maximum differential pressure: 3.1 bar (45 psi)* * Up to 12 hours at 25 °C; up to 6 hours at 40 °C Sterilization Gamma >25 kGy Shelf Life 3 (three) years Liquid Flow vs. Differential Pressure (Typical) 1.4 – 2.6 mL/min at 2.1 bard, water at 20 °C

STyLUX ilers 1 - Meissner

Maximum Operating Pressure & Temperature, Liquids Maximum Operating Pressure & Temperature, Gas 75 psig @ 32°F to 100°F 50 psig @ 32°F to 100°F (5,2 bar @ 0°C to 38°C) (3,4 bar @ 0°C to 38°C) 45 psig @ 140°F 30 psig @ 140°F (3,1 bar @ 60°C) (2,1 bar @ 60°C) UltraCap® H.D. Model

Disc Filtration

VEOLIA/SOLYS/BERKAL Filter/08.19 (190196) www.veoliawatertechnologies.com Maximum Operating Pressure 10 bar Minimum Downstream Pressure 1 bar Maximum Temperature 60°C Recommended Air Quality 270l/min at 6-8 bars Backwash volume without Air 12 l Recommended Air Quality 270l/min at 6-8 bars Maximum recommended Flow rate (m⁳/h)* Empty weight

GH Series High Pressure Compressed Air Filter (for pressures

Maximum Flow Rate: 365 to 4261 (@350 barg) m3/hour, 214 @ 5076 psig to 2507 @ 5076 psig CFM. Maximum Operating Pressure: 350 barg, 5076 psig. Maximum Operating Temperature: 176 or 104 for filters with activated carbon elements °F. Minimum Operating Temperature: 1.5 °C, 34.7 °F.

Fluorodyne® EX Grade EDF Filters,Fluorodyne® EX Grade EDF Filters

Filter Membrane Prefilter Layer: Hydrophilic asymmetric PES Final Filter Layer: Hydrophilic PVDF Housing, Vent Plug Polypropylene and Support Material Sealing Technology Insert molding Operating Parameters 1 Maximum Operating 5.4 bar (80 psi) at 20 °C Temperature and Pressure f2.1 bar (30 psi) at 60 °C 1I % ˙&$’ ˇ *!ˆ # ˛˚+ ˝ )- , ( /

FILTROMAX™ Disc

Maximum Operating Pressure⁽²⁾ bar 8 Maximum Operating Temperature⁽²⁾ °C 40 (1) Maximum recommended flow rate are worked out for a good quality water. Please ask SOLYS for more information. (2) These values can be increased to either 10 bars or 60° C. Please ask SOLYS for more information. Dimensions & Pipe Connections

Trinzik HCE Dilute Acid and Base Filters - Entegris

filter media, the advanced membrane design provides increased Maximum operating ... 2.1 bar (30 psid) @ 60°C (140°F) Maximum reverse differential pressure:

Advantec 43303020 Polypropylene Filter Holder for 47-mm

Jan 31, 2022 · PALL 1119 Polycarbonate in-Line Filter Holder for 47 mm Filter Disc, Non-Sterile, 3.4 bar Maximum Operating Pressure, 5.8 cm Length x 6.4 cm Diameter 4.7 out of 5 stars 3 1 offer from $116.00

Acrodisc wwPTFE Syringe Filters | Pall- MG - MG Scientific

Maximum Operating Temperature: 55°C (131°F) Maximum Operating Pressure: 0.2 and 0.45µm is 6.9 bar (100psi) GF/0.45µm is 6.3 bar (90 psi) Typical Water Flow Rate (mL/min at 2.1 bar (30psi)) 0.2µm, 25mm is 60 0.45µm, 25mm is 65 0.45µm, 25mm GF is 60: Typical Water Flow Rate (mL/min at 0.7 bar (10psi)) 0.2µm, 13mm is 17 0.45µm, 13mm is 28

Astera™ Liquid Filter | Liquid Filters | Entegris

Apr 01, 2021 · 0.21 MPa (2.1 bar; 30 psi) @ 25°C (77°F) Maximum operating pressure. 0.14 MPa (1.4 bar; 20 psi) @ 25°C (77°F) Maximum operating temperature. 70°C (158°F) @ 10 psi. Reference Materials Product Documentation. Published Apr 1, 2021 Data Sheet Astera™ Advanced Liquid Filters. Download PDF.

PureFlo® G50C Gas Filter Capsules

Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20°C) Maximum reverse differential pressure: 30 PSID (2.1 bar) at 68°F (20°C) Maximum Operating Temperature: