Home » News » GHP Filter » Certified ghp membrane maximum operating pressure 2.1 bar

Certified ghp membrane maximum operating pressure 2.1 bar

GH Polypro (GHP) Membrane Disc Filters – Separations Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point – Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 k...
Product Introduction

GH Polypro (GHP) Membrane Disc Filters - Separations

Maximum Operating Temperature 55 °C (131 °F) Minimum Bubble Point - Water 0.2 µm: 2.9 bar (290 kPa, 42 psi) 0.45 µm: 1.38 bar (138 kPa, 20 psi) Maximum versatility. Filters aqueous solutions or aggressive chemicals. Low protein binding membrane gives high recovery of critical proteinaceous samples. HPLC certified. Provides assurance

Dairy-Pro HpHT UF-10K and UF-5K ELEMENTS - Lenntech

The membrane used in the Dairy-Pro® UF elements consists of a semipermeable polyethersulfone (PES) layer on a polyolefin backing material. Operating Limits: Operating Pressure: Maximum operating pressure is listed on the first page of this document. Actual operating pressure is dependent upon system flux rate (application

Membrane Elements and Membrane Housings - Lenntech

membrane elements will fit a standard 2” x 12” residential membrane housing and are shipped dry for an indefinite shelf life and easier handling. Membrane elements may also be ordered as individually wet tested. Operating Limits Maximum Operating Temperature: 113°F (45°C) Maximum Operating Pressure: 150 psi (10 bar)

Steridyne

140 °F @ 30 psig (60 °C @ 2.1 bar), gas 75 psig @ 100 °F (5.2 bar @ 38 °C), liquid 50 psig @ 100 °F (3.4 bar @ 38 °C), gas 15 psig @ 100 °F (1.0 bar @ 38 °C) Operating temperature range: Maximum temperature rating: Maximum temperature rating: Maximum operating pressure: Maximum operating pressure: Maximum reverse pressure:

Atlantis Premier BEH C18 AX Columns

This will result in higher operating pressure and poorer performance. d. Pressure 2.1 mm I. D. Atlantis Premier BEH C 18 AX 1.7 µm and 2.5 µm columns can tolerate operating pressures up to 18000 psi (1241 bar or 124 MPa). The 4.6 mm i.d. columns containing 2.5 µm and 5 µm particles can tolerate pressures up to 10,000 psi (700 bar or 70 MPa).

Product Information: Pleated Capsules with Versapor Membrane

Maximum Operating Temperature 88 °C (190 °F) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure 3.4 bar (340 kPa, 50 psi) at ambient temperature Typical Water Flow Rate 9.5-11.4 Lpm at 0.3 bar (30 kPa, 5 psi) Biological Safety Materials of construction pass USP Biological Reactivity Test, In Vivo<88> Sterilization

Acrodisc® Syringe Filters with GHP Membrane - HPLC/UHPLC

Maximum Operating Temperature. 25 mm PSF: 55 ºC (131 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure. 13 mm: 6.3 bar (630 kPa, 90 psi) 25 mm PSF: 4.1 bar (410 kPa, 60 psi) at 21 - 24 ºC (70 - 75 ºF); 2.1 bar (210 kPa, 30 psi) at 55 ºC (131 ºF) Typical Water Flow Rate. mL/min at 0.7 bar (70 kPa, 10 psi) 13 mm, 0.2 µm: 17

(PDF) Effect of Operating Conditions on Reverse Osmosis (RO

The operating conditions using RO membrane . 2.1 Materials. ... (the testing condition: 15.5 bar pressure, 2000 ppm NaCl feed and 25 °C). Additionally, an unexpected phenomenon was found ...

FOOD & DAIRY UF ELEMENTS - Lenntech

OPERATING AND DESIGN INFORMATION* * Consult KMS Process Technology Group for specific applications. Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) Maximum Operating Pressure: 140 psi (9.7 bar) General Operating Temperature Range: 41 - 131°F (5 - 55°C) For the M100 and M180, Maximum Operating Temperature: At pH 6.0 - 7.5: 150°F (65

DATASHEET Sani-Pro HFK Ultrafiltration Elements

Operating Pressure: Maximum operating pressure is 140 psi (9.7 bar). Permeate Pressure: Permeate pressure should not exceed baseline (concentrate) pressure at any time (including online, off -line and during transition). Reverse pressure will damage the membrane. Differential Pressure: The maximum differential pressure per element is listed on

Aquatasr Plus XL - Sartorius

Diffusion at 1.5 bar | 22 psi [ml/min] Min. Bubble Point [bar | psi] Cartridges Size 2 1.6 m2 | 17.2 ft 2 50 2.8 | 40.5 Size 3 2.4 m2 | 25.8 ft 2 75 2.8 | 40.5 Max. Allowable Differential Pressure Cartridges 5 bar | 72.5 psi at 20°C 2 bar | 29 psi at 80°C Materials Prefilter Membrane Polyethersulfone, asymmetric Endfilter Membrane

Acrodisc® 25 mm Syringe Filter, 0.45 µm PTFE Membrane, 1000

Maximum Operating Pressure (bar) 2.1 bar. Maximum Operating Temperature (Metric) 100 °C. Typical Flow Rate.

Acrodisc® PSF Syringe Filters

AP-4364 GHP 0.2 µm < 125 µL 55 °C (131 °F) at 2.1 bar 4.1 bar (410 kPa, 60 psi) 215 mL/min at 2.1 bar AP-4564 (210 kPa, 30 psi) at 21-24 °C (70-75 °F) (210 kPa, 30 psi) AP-4566

Acrodisc Syringe Filter PALL | High Performance Liquid

Acrodisc Syringe Filters with GHP Membrane and SOTAX* Automation Certified to ensure smooth ... at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure ...

Acrodisc® Syringe Filters with Versapor® Membrane

Maximum Operating Temperature 0.8 µm: 55 °C (131 °F) at 2.1 bar (210 kPa, 30 psi) 10 µm: 82 ºC (180 ºF) at 2.1 bar (210 kPa, 30 psi) Maximum Operating Pressure